[Process management and controlling in diagnostic radiology in the hospital].

P Gocke1, J F Debatin, L F J Dürselen.   

Abstract

Systematic process management and efficient quality control is rapidly gaining importance in our healthcare system. What does this mean for diagnostic radiology departments? To improve efficiency, quality and productivity the workflow within the department of diagnostic and interventional radiology at the University Hospital of Essen were restructured over the last two years. Furthermore, a controlling system was established. One of the pursued aims was to create a quality management system as a basis for the subsequent certification according to the ISO EN 9001:2000 norm. Central to the success of the workflow reorganisation was the training of selected members of the department's staff in process and quality management theory. Thereafter, a dedicated working group was created to prepare the reorganisation and the subsequent ISO certification with the support of a consulting partner. To assure a smooth implementation of the restructured workflow and create acceptance for the required ISO-9001 documentation, the entire staff was familiarized with the basic ideas of process- and quality-management in several training sessions. This manuscript summarizes the basic concepts of process and quality management as they were taught to our staff. A direct relationship towards diagnostic radiology is maintained throughout the text.

Mesh:

Year:  2002        PMID: 12132120     DOI: 10.1007/s00117-002-0717-2

Source DB:  PubMed          Journal:  Radiologe        ISSN: 0033-832X            Impact factor:   0.635


  4 in total

1.  [Efficacy of x-ray assessment in emergency surgical departments: an evaluation in a level I trauma center].

Authors:  O Ackermann; A Wetter; E Chelangattucherry; I Emmanouilidis; C Rülander
Journal:  Unfallchirurg       Date:  2011-01       Impact factor: 1.000

2.  [Controlling instruments in radiology].

Authors:  M Maurer
Journal:  Radiologe       Date:  2013-10       Impact factor: 0.635

3.  Cost comparison of 111In-DTPA-octreotide scintigraphy and 68Ga-DOTATOC PET/CT for staging enteropancreatic neuroendocrine tumours.

Authors:  Nils F Schreiter; Winfried Brenner; Munenobu Nogami; Ralph Buchert; Alexander Huppertz; Ulrich-Frank Pape; Vikas Prasad; Bernd Hamm; Martin H Maurer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-09-17       Impact factor: 9.236

Review 4.  [Integrated care concepts and multidisciplinary process chains in a radiological context].

Authors:  J Bauer; E Kösel; A G Henkel; C D Spinner; R Kolisch
Journal:  Radiologe       Date:  2022-02-24       Impact factor: 0.635

  4 in total