Abstract

Manual reduction and antegrade intramedullary K-wire fixation were performed for 29 selected Colles-type distal radial fractures in 29 patients. Severely comminuted intra-articular fractures and Barton's fracture were not included in this study. The tips of the K-wires supported an articular surface of the distal radius. Except for 1 case of skin irritation in the forearm, there were no complications related to tendon or nerve injuries or reflex dystrophy. There was no pin loosening, but protrusion of sharp tips of K-wires into the wrist joint occurred in 3 patients. Average volar tilt, radial shortening, and step-off at follow-up evaluation were 5 degrees, 2.6 mm, and 0.2 mm, respectively. These radiologic results were consistent with values reported in other pinning studies; however, radial shortening was not controlled effectively. Fourteen (48%) of 29 patients had radial shortening >3 mm. The advantages of this surgical procedure are the low occurrence rate of soft-tissue complications and prevention of dorsal angulation of fractures.

Entities:  

Mesh:

Year:  2002        PMID: 12132100     DOI: 10.1053/jhsu.2002.34371

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  7 in total

1.  [Fracture of the distal ulna accompanying fracture of the distal radius. Minimally invasive treatment with elastic stable intramedullary nailing (ESIN)].

Authors:  M Walz; B Kolbow; G Möllenhoff
Journal:  Unfallchirurg       Date:  2006-12       Impact factor: 1.000

2.  External fixation with or without supplementary intramedullary Kirschner wires in the treatment of distal radial fractures.

Authors:  Charles Lin; Jui-Sheng Sun; Sheng-Mou Hou
Journal:  Can J Surg       Date:  2004-12       Impact factor: 2.089

3.  [Fractures of the distal radius. Minimally invasive pin fixation: indications and results].

Authors:  L Lindemann-Sperfeld; F Pilz; I Marintschev; W Otto
Journal:  Chirurg       Date:  2003-11       Impact factor: 0.955

4.  Intramedullary Fixation of Distal Radius Fractures Using CAGE-DR Implant.

Authors:  Schneider K Rancy; Stephanie D Malliaris; Eric A Bogner; Scott W Wolfe
Journal:  J Wrist Surg       Date:  2018-09-18

5.  Do K-wires made from shape memory alloys increase pull-out forces? A preliminary experimental cadaver study in bovine bone.

Authors:  U Wiebking; T Gösling; W Monschizada; T Rau; C Krettek
Journal:  Med Biol Eng Comput       Date:  2007-05-31       Impact factor: 3.079

6.  Treatment of distal radial fractures with antegrade intra-medullary Kirschner wires.

Authors:  Mohamed F Mostafa
Journal:  Strategies Trauma Limb Reconstr       Date:  2013-06-06

7.  Distal Radial Fracture Fixation in Adults using Intramedullary Elastic Wires Augmented with either Cast Immobilisation or External Fixation.

Authors:  P Gadegone; W Gadegone; V Lokhande; N Jawrani
Journal:  Malays Orthop J       Date:  2021-11
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.