Literature DB >> 12132030

A prospective randomized trial comparing the safety and efficacy of three commercially available closure devices (Angioseal, Vasoseal and Duett).

Lampros K Michalis1, Michael R Rees, Demetrios Patsouras, Christos S Katsouras, John Goudevenos, Spyridon Pappas, Eleni Sourla, Theophilos Kolettis, Lampros Sioros, Paraskevi Zotou, Panoraia Gartzou-Matsouka, Dimitris A Sideris.   

Abstract

PURPOSE: We compared the safety and efficacy of three closure devices (Angioseal, Vasoseal and Duett) used to close arterial puncture sites in patients who underwent coronary percutaneous procedures.
METHODS: A prospective randomized, single-center trial was carried out of consecutive patients who underwent coronary angiography [705 patients: Angioseal (243),Vasoseal (228) and Duett (234)] or angioplasty [146 patients:Angioseal (47), Vasoseal (52) and Duett (47)].
RESULTS: In the angiography patients the device deployment rates were similar, with the Angioseal been significantly slower in achieving hemostasis (p = 0.0001) but resulting in earlier ambulation (p = 0.0001). In the coronary angioplasty patients the deployment rates were similar to those for angiography: time to hemostasis was longer for the Angioseal (p = 0.003), while ambulation times were not different, although prolonged compared with angiography (p = 0.0001). The three devices had similar major complication rates. The Vasoseal had a higher major complication rate after angioplasty than after angiography (p = 0.004). The incidence rate of peripheral embolization was lower when the Angioseal was utilized. Severe complications were mainly seen in patients who received abciximab.
CONCLUSIONS: The three closure devices had high rates of successful deployment and were relatively safe. The Angioseal resulted in earlier ambulation after angiography. Utilization of closure devices after abciximab administration possibly increased the complications.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12132030     DOI: 10.1007/s00270-002-1942-9

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  7 in total

1.  Occlusion of the femoral artery after using the percutaneous suture-mediated closure system perclose.

Authors:  H Kälsch; T Konorza; R Erbel
Journal:  Clin Res Cardiol       Date:  2006-09-08       Impact factor: 5.460

2.  Perioperative safety analysis of transcatheter arterial chemoembolization for hepatocellular carcinoma patients with preprocedural leukopenia or thrombocytopenia.

Authors:  Lin Zhou; Lin-Zhi Zhang; Jing-Yan Wang; Yong-Wu Li; Hai-Dong Hu; Xiao-Ming Peng; Yun Zhao; Xi-Ming Wang; Hui Xie; Chun-Zi Liu; Hua-Ming Wang
Journal:  Mol Clin Oncol       Date:  2017-07-25

3.  Randomized comparison of effects of suture-based and collagen-based vascular closure devices on post-procedural leg perfusion.

Authors:  H I M Kälsch; H Eggebrecht; S Mayringer; T Konorza; B Sievers; S Sack; R Erbel; K Kroeger
Journal:  Clin Res Cardiol       Date:  2007-09-18       Impact factor: 5.460

4.  Incidence of vascular injuries after use of the Angio-Seal closure device following endovascular procedures in a single center.

Authors:  Patrizio Castelli; Roberto Caronno; Gabriele Piffaretti; Matteo Tozzi; Chiara Lomazzi
Journal:  World J Surg       Date:  2006-03       Impact factor: 3.352

5.  Efficacy of femoral vascular closure devices in patients treated with anticoagulant, abciximab or thrombolytics during percutaneous endovascular procedures.

Authors:  Ha Young Kim; Sung Wook Choo; Hong Gee Roh; Heon Han; Sam Soo Kim; Ji Yeon Lee; Yul Ri Park; Sung Hoon Lee; Sung Wook Shin; Kwang Bo Park; Young Soo Do; Sung Ki Cho; In Ho Lee; Sung Mok Kim; Hong Sik Byun; Pyoung Jeon
Journal:  Korean J Radiol       Date:  2006 Jan-Mar       Impact factor: 3.500

Review 6.  Network Meta-analysis of Randomized Trials on the Safety of Vascular Closure Devices for Femoral Arterial Puncture Site Haemostasis.

Authors:  Jun Jiang; Junjie Zou; Hao Ma; Yuanyong Jiao; Hongyu Yang; Xiwei Zhang; Yi Miao
Journal:  Sci Rep       Date:  2015-09-08       Impact factor: 4.379

7.  Access site complications following transfemoral coronary procedures: comparison between traditional compression and angioseal vascular closure devices for haemostasis.

Authors:  Pei-Jung Wu; Yu-Tzu Dai; Hsien-Li Kao; Chin-Hao Chang; Meei-Fang Lou
Journal:  BMC Cardiovasc Disord       Date:  2015-05-09       Impact factor: 2.298

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.