Initial experience with ultrasound localization for positioning prostate cancer patients for external beam radiotherapy.

Christopher F Serago1, Suzanne J Chungbin, Steven J Buskirk, Gary A Ezzell, A Craig Collie, Sujay A Vora.   

Abstract

PURPOSE: Transabdominal ultrasound localization of the prostate gland and its immediate surrounding anatomy has been used to guide the positioning of patients for the treatment of prostate cancer. This process was evaluated in terms of (1) the reproducibility of the ultrasound measurement; (2) a comparison of patient position between ultrasound localization and skin marks determined from a CT treatment planning scan; (3) the predictive indicators of patient anatomy not well suited for ultrasound localization; (4) the measurement of prostate organ displacement resulting from ultrasound probe pressure; and (5) quality assurance measures. METHODS AND MATERIALS: The reproducibility of the ultrasound positioning process was evaluated for same-day repeat positioning by the same ultrasound operator (22 patients) and for measurements made by 2 different operators (38 patients). Differences between conventional patient positioning (CT localization with skin markings) and ultrasound-based positioning were determined for 38 patients. The pelvic anatomy was evaluated for 34 patients with pretreatment CT scans to identify predictors of poor ultrasound image quality. The displacement of the prostate resulting from pressure of the ultrasound probe was measured for 16 patients with duplicate CT scans with and without a simulated probe. Finally, daily, monthly, and semiannual quality assurance tests were evaluated.
RESULTS: Self-verification tests of ultrasound positioning indicated a shift of <3 mm in approximately 95% of cases. Interoperator tests indicated shifts of <3 mm in approximately 80-90% of cases. The mean difference in patient positioning between conventional and ultrasound localization for lateral shifts was 0.3 mm (SD 2.5): vertical, 1.3 mm (SD 4.7 mm) and longitudinal, 1.0 mm (SD 5.1). However, on a single day, the differences were >10 mm in 1.5% of lateral shifts, 7% of longitudinal shifts, and 7% of vertical shifts. The depth to the isocenter, thickness of tissue overlying the bladder, and position of the prostate relative to the pubic symphysis, but not the bladder volume, were significant predictive indicators of poor ultrasound imaging. The pressure of the ultrasound probe displaced the prostate in 7 of the 16 patients by an average distance of 3.1 mm; 9 patients (56%) showed no displacement. Finally, the quality assurance tests detected ultrasound equipment defects.
CONCLUSION: The ultrasound positioning system is reproducible and may indicate the need for significant positioning moves. Factors that predict poor image quality are the depth to the isocenter, thickness of tissue overlying the bladder, and position of the prostate relative to the pubic symphysis. The prostate gland may be displaced a small amount by the pressure of the ultrasound probe. A quality assurance program is necessary to detect ultrasound equipment defects that could result in patient alignment errors.

Entities:  

Mesh:

Year:  2002        PMID: 12128112     DOI: 10.1016/s0360-3016(02)02826-2

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  22 in total

1.  In vivo reproducibility of robotic probe placement for a novel ultrasound-guided radiation therapy system.

Authors:  Muyinatu A Lediju Bell; H Tutkun Sen; Iulian Iordachita; Peter Kazanzides; John Wong
Journal:  J Med Imaging (Bellingham)       Date:  2014-07-23

Review 2.  Current status of intensity-modulated radiation therapy (IMRT).

Authors:  Kazuo Hatano; Hitoshi Araki; Mitsuhiro Sakai; Takashi Kodama; Naoki Tohyama; Tohru Kawachi; Masaharu Imazeki; Takayuki Shimizu; Tsutomu Iwase; Minoru Shinozuka; Hideyo Ishigaki
Journal:  Int J Clin Oncol       Date:  2007-12-21       Impact factor: 3.402

3.  A novel approach for establishing benchmark CBCT/CT deformable image registrations in prostate cancer radiotherapy.

Authors:  Jinkoo Kim; Sanath Kumar; Chang Liu; Hualiang Zhong; Deepak Pradhan; Mira Shah; Richard Cattaneo; Raphael Yechieli; Jared R Robbins; Mohamed A Elshaikh; Indrin J Chetty
Journal:  Phys Med Biol       Date:  2013-10-31       Impact factor: 3.609

4.  Evaluation of uterine ultrasound imaging in cervical radiotherapy; a comparison of autoscan and conventional probe.

Authors:  Mariwan Baker; David T Cooper; Claus F Behrens
Journal:  Br J Radiol       Date:  2016-07-25       Impact factor: 3.039

Review 5.  The efficacy of conventional external beam, three-dimensional conformal, intensity-modulated, particle beam radiation, and brachytherapy for localized prostate cancer.

Authors:  Tony Y Eng; Join Y Luh; Charles R Thomas
Journal:  Curr Urol Rep       Date:  2005-05       Impact factor: 3.092

6.  Transurethral light delivery for prostate photoacoustic imaging.

Authors:  Muyinatu A Lediju Bell; Xiaoyu Guo; Danny Y Song; Emad M Boctor
Journal:  J Biomed Opt       Date:  2015-03       Impact factor: 3.170

7.  Dosimetric comparison of image guidance by megavoltage computed tomography versus bone alignment for prostate cancer radiotherapy.

Authors:  Jörn Kalz; Florian Sterzing; Kai Schubert; Gabriele Sroka-Perez; Jürgen Debus; Klaus Herfarth
Journal:  Strahlenther Onkol       Date:  2009-04-16       Impact factor: 3.621

8.  Reduced rectal toxicity with ultrasound-based image guided radiotherapy using BAT (B-mode acquisition and targeting system) for prostate cancer.

Authors:  Markus Bohrer; Peter Schröder; Grit Welzel; Hansjörg Wertz; Frank Lohr; Frederik Wenz; Sabine Kathrin Mai
Journal:  Strahlenther Onkol       Date:  2008-12-24       Impact factor: 3.621

9.  Image-guided radiotherapy for prostate cancer. Implementation of ultrasound-based prostate localization for the analysis of inter- and intrafraction organ motion.

Authors:  Michael Pinkawa; Martin Pursch-Lee; Branka Asadpour; Bernd Gagel; Marc D Piroth; Jens Klotz; Sandra Nussen; Michael J Eble
Journal:  Strahlenther Onkol       Date:  2008-12-24       Impact factor: 3.621

10.  Comparison of daily couch shifts using MVCT (TomoTherapy) and B-mode ultrasound (BAT System) during prostate radiotherapy.

Authors:  Steven H Lin; Elizabeth Sugar; Terrance Teslow; Todd McNutt; Habeeb Saleh; Danny Y Song
Journal:  Technol Cancer Res Treat       Date:  2008-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.