Literature DB >> 12121607

Bone reactions to oxidized titanium implants with electrochemical anion sulphuric acid and phosphoric acid incorporation.

Young-Taeg Sul1, Carina B Johansson, Yunmo Kang, Dong-Gyun Jeon, Tomas Albrektsson.   

Abstract

BACKGROUND: The importance of the surface properties of implants for a successful osseointegration has been emphasized. It is generally known that bone response to implant surfaces is considerably related to the various surface properties.
PURPOSE: The purpose of this study was to investigate bone tissue reactions to multifactorial biocompatibility of the surface oxide of electrochemically oxidized titanium implants. The ultimate objective was to improve surface quality, resulting in enhancement of clinical outcomes of osseointegrated implants.
MATERIALS AND METHODS: Three different surface types of commercially pure titanium (c.p. Ti) implants were prepared. Turned implants were used for controls and test implants were prepared by the micro arc oxidation (MAO) method, either in sulphuric acid (S implants) or in phosphoric acid (P implants). Implants were inserted in the femur and tibia of 10 mature New Zealand White rabbits. The bone response was evaluated by biomechanical tests, histology, and histomorphometry. The follow-up time was 6 weeks.
RESULTS: The mean peak values of the removal torque showed significant differences between control and test S implants (p =.022) but showed no significant differences between control and test P implants (p =.195) or between test S and test P implants (p =.457). In addition, the histomorphometric comparisons of the bone-to-metal contact around entire implants demonstrated 186% increase in S implants (p =.028) and 232% increase in P implants (p =.028) compared with the paired control groups. Quantification of the bone area in the threads did not show any significant differences.
CONCLUSIONS: The present results suggest that the primary mode of action in strong bone response to S implants is mechanical interlocking, and to P implants, it is biochemical interaction. It is possible that the phosphate groups in the titanium oxide of P implants provide potential chemical bonding sites for calcium ions and hydroxyapatite of the bone matrix during biologic mineralization. key words: bone responses, histomorphometry, oxidized implants, removal torque test, surface oxide properties

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12121607     DOI: 10.1111/j.1708-8208.2002.tb00156.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  19 in total

1.  Bone response to a titanium aluminium nitride coating on metallic implants.

Authors:  C O Freeman; I M Brook
Journal:  J Mater Sci Mater Med       Date:  2006-05       Impact factor: 3.896

Review 2.  Biomaterials and interface with bone.

Authors:  K Anselme
Journal:  Osteoporos Int       Date:  2011-06       Impact factor: 4.507

3.  Osseointegration of bioactive microarc oxidized amorphous phase/TiO2 nanocrystals composited coatings on titanium after implantation into rabbit tibia.

Authors:  Rui Zhou; Daqing Wei; Haoyue Yang; Su Cheng; Wei Feng; Baoqiang Li; Yaming Wang; Dechang Jia; Yu Zhou
Journal:  J Mater Sci Mater Med       Date:  2014-01-31       Impact factor: 3.896

4.  Real time assessment of surface interactions with a titanium passivation layer by surface plasmon resonance.

Authors:  Isao Hirata; Yasuhiro Yoshida; Noriyuki Nagaoka; Kyou Hiasa; Yasuhiko Abe; Kenji Maekawa; Takuo Kuboki; Yasumasa Akagawa; Kazuomi Suzuki; Bart Van Meerbeek; Phillip B Messersmith; Masayuki Okazaki
Journal:  Acta Biomater       Date:  2011-12-02       Impact factor: 8.947

5.  Electrochemical growth behavior, surface properties, and enhanced in vivo bone response of TiO2 nanotubes on microstructured surfaces of blasted, screw-shaped titanium implants.

Authors:  Young-Taeg Sul
Journal:  Int J Nanomedicine       Date:  2010-04-15

6.  Histomorphometry and stability analysis of early loaded implants with two different surface conditions in beagle dogs.

Authors:  Dong-Seok Kim; Dae-Gon Kim; Chan-Jin Park; Lee-Ra Cho
Journal:  J Adv Prosthodont       Date:  2009-03-31       Impact factor: 1.904

7.  Effect of surface anodization on stability of orthodontic microimplant.

Authors:  Sanket Karmarker; Wonjae Yu; Hee-Moon Kyung
Journal:  Korean J Orthod       Date:  2012-02-27       Impact factor: 1.372

8.  Implant-retained craniofacial prostheses for facial defects.

Authors:  Philipp A Federspil
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2011-03-10

9.  Anodisation Increases Integration of Unloaded Titanium Implants in Sheep Mandible.

Authors:  Warwick J Duncan; Min-Ho Lee; Tae-Sung Bae; Sook-Jeong Lee; Jennifer Gay; Carolina Loch
Journal:  Biomed Res Int       Date:  2015-09-08       Impact factor: 3.411

10.  The effects of different wavelength UV photofunctionalization on micro-arc oxidized titanium.

Authors:  Yan Gao; Ying Liu; Lei Zhou; Zehong Guo; Mingdeng Rong; Xiangning Liu; Chunhua Lai; Xianglong Ding
Journal:  PLoS One       Date:  2013-07-05       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.