Literature DB >> 12120776

Surface texture of resin-modified glass ionomer cements: effects of finishing/polishing systems.

Adrian U J Yap1, W S Tan, J C Yeo, W Y Yap, S B Ong.   

Abstract

This study investigated the surface texture of two resin-modified glass ionomer cements (RMGICs) in the vertical and horizontal axis after treatment with different finishing/polishing systems. Class V preparations were made on the buccal and lingual/palatal surfaces of freshly extracted teeth. The cavities on each tooth were restored with Fuji II LC (GC) and Photac-Fil Quick (ESPE) according to manufacturers' instructions. Immediately after light-polymerization, gross finishing was done with 8-flute tungsten carbide burs. The teeth were then randomly divided into four groups and finished/polished with (a) Robot Carbides (RC); (b) Super-Snap system (SS); (c) OneGloss (OG) and (d) CompoSite Points (CS). The sample size for each material-finishing/polishing system combination was eight. The mean surface roughness (microm) in vertical (RaV) and horizontal (RaH) axis was measured using a profilometer. Data was subjected to ANOVA/Scheffe's tests and Independent Samples t-test at significance level 0.05. Mean RaV ranged from 0.59-1.31 and 0.83-1.52, while mean RaH ranged from 0.80-1.43 and 0.85-1.58 for Fuji II LC and Photac-Fil, respectively. Results of statistical analysis were as follows: Fuji II LC: RaV-RC, SS<OG & SS<CS; RaH-SS, CS<RC, OG; Photac-Fil: RaV- SS, CS<OG; RaH-SS<RC, OG & CS<RC (where < indicates significantly greater Ra values). Significant differences in RaV and RaH values were observed when Fuji II LC was finished with RC. The use of carbides (RC) and one-step rubber abrasive system (OG) for finishing/polishing of RMGICs is not recommended. Graded abrasive disk (SS) or two-step rubber abrasive (CS) systems should be used instead.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12120776

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  3 in total

Review 1.  Review: finishing and polishing procedures of (resin-modified) glass ionomers and compomers in paediatric dentistry.

Authors:  N S Koupis; L A M Marks; R M H Verbeeck; L C Martens
Journal:  Eur Arch Paediatr Dent       Date:  2007-03

2.  Surface roughness of glass ionomer cements indicated for uncooperative patients according to surface protection treatment.

Authors:  Edoardo Pacifici; Maurizio Bossù; Agostino Giovannetti; Giuseppe La Torre; Fabrizio Guerra; Antonella Polimeni
Journal:  Ann Stomatol (Roma)       Date:  2014-02-04

3.  Effect of Hydroxyapatite on Surface Roughness of Zirconomer, and Conventional and Resin-Modified Glass Ionomers.

Authors:  Farahnaz Sharafeddin; Somaye Bahrani
Journal:  Front Dent       Date:  2020-12-20
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.