Literature DB >> 12119534

Use of near infrared spectroscopy for estimation of peripheral venous saturation in newborns: comparison with co-oximetry of central venous blood.

Rikke Bay-Hansen1, Betina Elfving, Gorm Greisen.   

Abstract

In the intensive care of sick infants, the global oxygen reserve capacity is estimated by co-oximetry (co-ox) of blood sampled from central venous catheters. Introduction of a noninvasive alternative is desirable. Near infrared spectroscopy (NIRS) offers a technique for noninvasive bedside monitoring of tissue oxygen economy. We studied the relation between peripheral venous oxyhemoglobin saturation (SvO(2)) estimated by venous occlusion and NIRS, and the central SvO(2) measured by co-ox of central venous blood. We report the high reproducibility of NIRS with a test-retest variation of only 2.51 +/- 1.41%. After bias adjusting of NIRS SvO(2) values, a nice correlation (r = 0.96, p > 0.05) between NIRS measurements of peripheral SvO(2) and co-ox of central venous blood was found. The study indicates that NIRS is practical for monitoring relative changes in central venous saturation. This might be useful in the future clinical care of newborns. Copyright 2002 S. Karger AG, Basel

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12119534     DOI: 10.1159/000064145

Source DB:  PubMed          Journal:  Biol Neonate        ISSN: 0006-3126


  5 in total

1.  Does treatment of patent ductus arteriosus with cyclooxygenase inhibitors affect neonatal regional tissue oxygenation?

Authors:  Mayoor Bhatt; Anna Petrova; Rajeev Mehta
Journal:  Pediatr Cardiol       Date:  2012-04-01       Impact factor: 1.655

2.  pFOE or pFTOE as an Early Marker for Impaired Peripheral Microcirculation in Neonates.

Authors:  Nina Hoeller; Christina H Wolfsberger; Daniel Pfurtscheller; Corinna Binder-Heschl; Bernhard Schwaberger; Berndt Urlesberger; Gerhard Pichler
Journal:  Children (Basel)       Date:  2022-06-16

3.  Clinical practice parameters for hemodynamic support of pediatric and neonatal septic shock: 2007 update from the American College of Critical Care Medicine.

Authors:  Joe Brierley; Joseph A Carcillo; Karen Choong; Tim Cornell; Allan Decaen; Andreas Deymann; Allan Doctor; Alan Davis; John Duff; Marc-Andre Dugas; Alan Duncan; Barry Evans; Jonathan Feldman; Kathryn Felmet; Gene Fisher; Lorry Frankel; Howard Jeffries; Bruce Greenwald; Juan Gutierrez; Mark Hall; Yong Y Han; James Hanson; Jan Hazelzet; Lynn Hernan; Jane Kiff; Niranjan Kissoon; Alexander Kon; Jose Irazuzta; Jose Irazusta; John Lin; Angie Lorts; Michelle Mariscalco; Renuka Mehta; Simon Nadel; Trung Nguyen; Carol Nicholson; Mark Peters; Regina Okhuysen-Cawley; Tom Poulton; Monica Relves; Agustin Rodriguez; Ranna Rozenfeld; Eduardo Schnitzler; Tom Shanley; Saraswati Kache; Sara Skache; Peter Skippen; Adalberto Torres; Bettina von Dessauer; Jacki Weingarten; Timothy Yeh; Arno Zaritsky; Bonnie Stojadinovic; Jerry Zimmerman; Aaron Zuckerberg
Journal:  Crit Care Med       Date:  2009-02       Impact factor: 7.598

4.  The Predictive Value of Pulse Oximeters for Pulse Improvement after Angiography in Infants and Children.

Authors:  Mohammad-Reza Alipour; Mazyar Rastegar; Mehdi Ghaderian; Seyedeh-Mahdieh Namayandeh; Reza Faraji; Zohreh Pezeshkpour
Journal:  Iran J Pediatr       Date:  2016-07-10       Impact factor: 0.364

5.  Peripheral fractional oxygen extraction measured with near-infrared spectroscopy in neonates-A systematic qualitative review.

Authors:  Christina H Wolfsberger; Nina Hoeller; Ena Suppan; Bernhard Schwaberger; Berndt Urlesberger; Britt Nakstad; Gerhard Pichler
Journal:  Front Pediatr       Date:  2022-08-23       Impact factor: 3.569