Literature DB >> 12119333

Iliac artery kinking with endovascular therapies: technical considerations.

David L Dawson1, Jeffrey C Hellinger, Thomas T Terramani, Sasan Najibi, Louis G Martin, Alan B Lumsden.   

Abstract

Iliac artery tortuosity should be considered when planning endovascular interventions from a femoral approach. Stiff guide wires across tortuous iliac segments can introduce foreshortening and temporary kinking. Recognition of this phenomenon and its implications is important when making anatomic measurements before endovascular device placement, when assessing iliac runoff, and when considering adjunctive procedures after aortoiliac interventions. Two illustrative cases of external iliac artery kinking are presented, one during an abdominal aortic aneurysm endograft procedure and another encountered during stent placement in an external iliac artery dissection. In both cases, the temporary nature of the deformity was recognized, avoiding unnecessary additional intervention.

Entities:  

Mesh:

Year:  2002        PMID: 12119333     DOI: 10.1016/s1051-0443(07)61852-1

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  7 in total

Review 1.  Twisted blood vessels: symptoms, etiology and biomechanical mechanisms.

Authors:  Hai-Chao Han
Journal:  J Vasc Res       Date:  2012-03-14       Impact factor: 1.934

2.  Unique operative approach for dealing with a tortuous external iliac artery during abdominal aortic aneurysm endografting.

Authors:  Randall W Franz
Journal:  Int J Angiol       Date:  2009

3.  Effects of elastin degradation and surrounding matrix support on artery stability.

Authors:  Avione Y Lee; Boyang Han; Shawn D Lamm; Cesar A Fierro; Hai-Chao Han
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-12-09       Impact factor: 4.733

4.  A biomechanical model of artery buckling.

Authors:  Hai-Chao Han
Journal:  J Biomech       Date:  2007-08-08       Impact factor: 2.712

Review 5.  Artery buckling: new phenotypes, models, and applications.

Authors:  Hai-Chao Han; Jennifer K W Chesnutt; Justin R Garcia; Qin Liu; Qi Wen
Journal:  Ann Biomed Eng       Date:  2012-11-29       Impact factor: 3.934

6.  Increased tortuosity of ACA might be associated with increased risk of ACoA aneurysm development and less aneurysm dome size: a computer-aided analysis.

Authors:  Roger M Krzyżewski; Kornelia M Kliś; Borys M Kwinta; Małgorzata Gackowska; Jerzy Gąsowski
Journal:  Eur Radiol       Date:  2019-04-11       Impact factor: 5.315

7.  Severe accordion effect: Myocardial ischemia due to wire complication during percutaneous coronary intervention: A case report.

Authors:  Gerasimos Gavrielatos; Loukas K Pappas; Prodromos Anthopoulos; Anastasios Salachas; Georgios Ifantis; Ioannis Antonellis
Journal:  Cases J       Date:  2008-09-02
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.