Literature DB >> 12113567

Posterior capsular opacification in pseudophakic eyes with a silicone or acrylic intraocular lens.

T Pohjalainen1, E Vesti, R J Uusitalo, L Laatikainen.   

Abstract

PURPOSE: To compare posterior capsular opacification in eyes with IOL of two different materials--silicone or acrylic.
METHODS: Eighty consecutive eyes undergoing cataract surgery were prospectively randomized in two groups, 40 eyes receiving a silicone (Sl--30NB) and 40 eyes an acrylic (Acrysof MA60BM) intraocular lens (IOL). The same surgeon performed phacoemulsification and the intraocular lens (PHACO IOL) operation in all cases. Patients were re-examined on the first postoperative day, after one week, four months, and 1-2.4 years. Seven eyes were lost to late control.
RESULTS: Clinically significant posterior capsular opacification (PCO) (including eyes with capsulotomy already performed) was equally common in both groups; 25% in the silicone group and 19% in the acrylic group (p=0.53). The posterior capsule remained clear in 61% of the silicone and 76% of the acrylic IOL eyes (p=0.18). In the whole study group, 29% of eyes with and 14% without concurrent ocular diseases had significant PCO (p=0.13). In the silicone IOL group, PCO was more common in eyes with concurrent ocular diseases (44%) than eyes without other diseases (10%) (p=0.049). Eyes with acrylic IOL showed no difference in significant PCO, with or without other diseases (18% and 20%, respectively).
CONCLUSIONS: In a consecutive series of 80 cataract eyes central PCO was equally common in eyes receiving a silicone or an acrylic IOL. In the silicone IOL group, however, significant PCO was more common if there was concurrent ocular disease, while with the acrylic IOL concurrent ocular disease did not seem to increase the risk of PCO.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12113567     DOI: 10.1177/112067210201200307

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  3 in total

1.  [Quantitative evaluation of acrylic and silicone intraocular lenses with a sharp optic edge design].

Authors:  T M Rabsilber; A J Reuland; B B Entz; M P Holzer; I J Limberger; G U Auffarth
Journal:  Ophthalmologe       Date:  2006-01       Impact factor: 1.059

Review 2.  Posterior Capsule Opacification after Cataract Surgery via Implantation with Hydrophobic Acrylic Lens Compared with Silicone Intraocular Lens: A Systematic Review and Meta-Analysis.

Authors:  Ye Rin Kwon; Yoo Na Hwang; Sung Min Kim
Journal:  J Ophthalmol       Date:  2022-02-25       Impact factor: 1.909

3.  A meta-analysis of Nd:YAG capsulotomy rates for two hydrophobic intraocular lens materials.

Authors:  Mark Von Tress; James S Marotta; Stephen S Lane; Ramesh Sarangapani
Journal:  Clin Ophthalmol       Date:  2018-06-22
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.