Literature DB >> 12113378

Evolution of dry powder inhaler design, formulation, and performance.

S P Newman1, W W Busse.   

Abstract

Many companies are now prioritizing the development of dry powder inhalers (DPIs) above pressurized formulations of asthma drugs. A well-designed DPI and an appropriate powder formulation can optimize the effectiveness of inhaled drug therapy. A DPI must be able to deliver medications effectively for most patients, and an ideal inhaler would provide a dose that does not vary with inspiratory flow rate. Recent regulatory guidelines, among which the U.S. FDA draft guidance is the most stringent, demand consistent dose delivery from an inhaler throughout its life and consistency of doses from one inhaler to another. However, the properties of free micronized powders often interfere with drug handling and with drug delivery reducing dose consistency. Recent advances in formulation technology can increase lung dose and reduce its variability. While a perfect DPI may never exist, both device and formulation technology are evolving to rectify perceived deficiencies in earlier systems.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12113378     DOI: 10.1053/rmed.2001.1276

Source DB:  PubMed          Journal:  Respir Med        ISSN: 0954-6111            Impact factor:   3.415


  57 in total

1.  Investigation into the influence of primary crystallization conditions on the mechanical properties and secondary processing behaviour of fluticasone propionate for carrier based dry powder inhaler formulations.

Authors:  Harshal A Kubavat; Jagdeep Shur; Graham Ruecroft; David Hipkiss; Robert Price
Journal:  Pharm Res       Date:  2011-12-09       Impact factor: 4.200

2.  Comparing MDI and DPI aerosol deposition using in vitro experiments and a new stochastic individual path (SIP) model of the conducting airways.

Authors:  P Worth Longest; Geng Tian; Ross L Walenga; Michael Hindle
Journal:  Pharm Res       Date:  2012-06       Impact factor: 4.200

3.  Condensational growth of combination drug-excipient submicrometer particles for targeted high efficiency pulmonary delivery: comparison of CFD predictions with experimental results.

Authors:  P Worth Longest; Michael Hindle
Journal:  Pharm Res       Date:  2011-09-27       Impact factor: 4.200

4.  Effect of device design on the in vitro performance and comparability for capsule-based dry powder inhalers.

Authors:  Jagdeep Shur; Sau Lee; Wallace Adams; Robert Lionberger; James Tibbatts; Robert Price
Journal:  AAPS J       Date:  2012-06-22       Impact factor: 4.009

5.  Particle aerosolisation and break-up in dry powder inhalers 1: evaluation and modelling of venturi effects for agglomerated systems.

Authors:  William Wong; David F Fletcher; Daniela Traini; Hak-Kim Chan; John Crapper; Paul M Young
Journal:  Pharm Res       Date:  2010-04-06       Impact factor: 4.200

6.  Effect of Device Design and Formulation on the In Vitro Comparability for Multi-Unit Dose Dry Powder Inhalers.

Authors:  Jagdeep Shur; Bhawana Saluja; Sau Lee; James Tibbatts; Robert Price
Journal:  AAPS J       Date:  2015-05-09       Impact factor: 4.009

Review 7.  Particle engineering for pulmonary drug delivery.

Authors:  Albert H L Chow; Henry H Y Tong; Pratibhash Chattopadhyay; Boris Y Shekunov
Journal:  Pharm Res       Date:  2007-03       Impact factor: 4.200

Review 8.  Inhaled drug delivery for tuberculosis therapy.

Authors:  Pavan Muttil; Chenchen Wang; Anthony J Hickey
Journal:  Pharm Res       Date:  2009-11       Impact factor: 4.200

9.  Distribution and Cellular Uptake of PEGylated Polymeric Particles in the Lung Towards Cell-Specific Targeted Delivery.

Authors:  Tammy W Shen; Catherine A Fromen; Marc P Kai; J Christopher Luft; Tojan B Rahhal; Gregory R Robbins; Joseph M DeSimone
Journal:  Pharm Res       Date:  2015-05-23       Impact factor: 4.200

Review 10.  Spacer devices for metered dose inhalers.

Authors:  Stephen P Newman
Journal:  Clin Pharmacokinet       Date:  2004       Impact factor: 6.447

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.