Literature DB >> 12113300

Multicenter evaluation of a fully mechanized soluble transferrin receptor assay on the Hitachi and cobas integra analyzers. the determination of reference ranges.

Susanne Kolbe-Busch1, Johannes Lotz, Gerd Hafner, Norbert J C Blanckaert, Georg Claeys, Giovanni Togni, Jürgen Carlsen, Ralf Röddiger, Lothar Thomas.   

Abstract

Soluble transferrin receptor (sTfR) is reported to be a reliable marker for the diagnosis of iron deficiency, especially when iron metabolism is influenced by inflammatory disorders such as infection, chronic inflammation and cancer-related anemia. In the present multicenter study the analytical performance of a recently introduced, latex-enhanced immunoturbidimetric assay for the determination of soluble transferrin receptor (Tina quant [a] sTfR, Roche Diagnostics) on different fully mechanized analyzers such as Hitachi 917 and 911, and Cobas Integra 400 and 700 was evaluated. Within-run and between-run imprecision showed good results (CV<5% and <7%, respectively). The assay was found to be linear over a wide measuring range (0.4-35 mg/l). Endogenous substances did not interfere with the test results. Comparison of serum sTfR concentrations with those of heparinized plasma revealed good correlation (r>0.976). Method comparison with an existing fully mechanized method as well as with ELISA tests for sTfR showed very good correlation (r>0.987). Because of the lack of international standardization the results differed from each other up to 2.5-fold. The 95% of serum levels in healthy individuals ranged from 1.9 to 4.4 mg/l (n=427). However, the reference ranges should be reported in a sex-dependent manner, as 2.2-5.0 mg/l for men (n=211) and as 1.9-4.4 mg/l for premenopausal (n=216) and postmenopausal (n=45) women. The Tina quant [a] sTfR assay enables the precise, accurate, rapid and convenient determination of sTfR concentrations for routine clinical chemistry purposes.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12113300     DOI: 10.1515/CCLM.2002.091

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  8 in total

1.  Lower Plasma Soluble Transferrin Receptor Range in Healthy Indian Pediatric Cohort as Compared to Asian and Western Data.

Authors:  P Bhatia; D Siyaram; R Marathe; D Dayal
Journal:  Indian J Hematol Blood Transfus       Date:  2016-08-19       Impact factor: 0.900

2.  Soluble transferrin receptor can predict all-cause mortality regardless of anaemia and iron storage status.

Authors:  Minjung Kang; Soie Kwon; Whanhee Lee; Yaerim Kim; Eunjin Bae; Jeonghwan Lee; Jae Yoon Park; Yong Chul Kim; Eun Young Kim; Dong Ki Kim; Chun Soo Lim; Yon Su Kim; Jung Pyo Lee
Journal:  Sci Rep       Date:  2022-07-13       Impact factor: 4.996

3.  The prevalence of anemia and iron deficiency is more common in breastfed infants than their mothers in Bhaktapur, Nepal.

Authors:  R K Chandyo; S Henjum; M Ulak; A L Thorne-Lyman; R J Ulvik; P S Shrestha; L Locks; W Fawzi; T A Strand
Journal:  Eur J Clin Nutr       Date:  2015-12-02       Impact factor: 4.016

4.  Maternal Micronutrient Supplementation and Long Term Health Impact in Children in Rural Bangladesh.

Authors:  Tania Mannan; Sultan Ahmed; Evana Akhtar; Anjan Kumar Roy; Md Ahsanul Haq; Adity Roy; Maria Kippler; Eva-Charlotte Ekström; Yukiko Wagatsuma; Rubhana Raqib
Journal:  PLoS One       Date:  2016-08-18       Impact factor: 3.240

5.  Is Erythrocyte Protoporphyrin a Better Single Screening Test for Iron Deficiency Compared to Hemoglobin or Mean Cell Volume in Children and Women?

Authors:  Zuguo Mei; Rafael C Flores-Ayala; Laurence M Grummer-Strawn; Gary M Brittenham
Journal:  Nutrients       Date:  2017-05-31       Impact factor: 5.717

6.  The effect of donation activity dwarfs the effect of lifestyle, diet and targeted iron supplementation on blood donor iron stores.

Authors:  Muriel Lobier; Johanna Castrén; Pia Niittymäki; Elina Palokangas; Jukka Partanen; Mikko Arvas
Journal:  PLoS One       Date:  2019-08-13       Impact factor: 3.240

7.  Analytical evaluation of three soluble transferrin receptor measurement systems for diagnosis of iron deficiency anemia: A retrospective study.

Authors:  Li'an Hou; Jun Lu; Xianyong Jiang; Xiuzhi Guo; Chaochao Ma; Xinqi Cheng
Journal:  J Clin Lab Anal       Date:  2020-04-22       Impact factor: 2.352

8.  Iron-containing micronutrient supplementation of Chinese women with no or mild anemia during pregnancy improved iron status but did not affect perinatal anemia.

Authors:  Zuguo Mei; Mary K Serdula; Jian-Meng Liu; Rafael C Flores-Ayala; Linlin Wang; Rongwei Ye; Laurence M Grummer-Strawn
Journal:  J Nutr       Date:  2014-04-17       Impact factor: 4.687

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.