Literature DB >> 12112746

Application of 1-alkylamines to a liquid chromatographic/turbo ionspray tandem mass spectrometric method for quantifying metabolites of a new bone anabolic agent, TAK-778, in human serum.

Koichiro Teshima1, Takahiro Kondo, Chie Maeda, Tsuneo Oda, Toshiaki Hagimoto, Ryoichi Tsukuda, Yoshinobu Yoshimura.   

Abstract

We investigated the application of alkylamines, as additives to the mobile phase, to a quantification method for the metabolites, M-III and M-IV, of TAK-778, which is a new bone anabolic agent, in human serum using liquid chromatography/tandem mass spectrometry (LC/MS/MS). Prior to setting up the analytical method, we found that 1-alkylamines co-existing with M-III and M-IV in the turbo ionsprayed solution formed 1-alkylammonium adduct molecules of these metabolites during the ionization process, and the abundance of the adduct ions was considerably higher than that of protonated molecules ([M + H](+)s) of these metabolites. Based on these findings, we investigated a variety of 1-alkylamines and their spiked concentrations in the mobile phase for LC/MS/MS analysis to obtain higher sensitivities for the quantification of these metabolites. After these examinations, we found that 1-hexylamine at a final concentration of 0.05 mmol l(-1) was the most suitable additive for the mobile phase, and set the selected reaction monitoring (SRM) ions for the 1-hexylammonium adduct molecule and [M + H](+), allowing about a fivefold gain in the SRM chromatographic peak compared with that without 1-hexylamine. The adduct ion was considered to be formed by interaction between the amino group of 1-hexylamine and the phosphoryl group of M-III and M-IV. The internal standard (I.S.) used was deuterated M-III for each metabolite. The analytes and I.S. were extracted with diethyl ether from serum samples at neutral pH and injected into the LC/MS/MS system with a turbo ionspray interface. The limit of quantification for both analytes was 0.5 ng ml(-1) when 0.1 ml of serum was used, and the calibration curves were linear in the range 0.5-100 ng ml(-1). The method was precise; the intra- and inter-day precisions of the method were not more than 5.6%. The accuracy of the method was good, with deviations between added and calculated concentrations of M-III and M-IV being typically within 16.6%. This method provided reliable pharmacokinetic data for M-III and M-IV after the intramuscular administration of TAK-778 sustained-release formulation in humans. Copyright 2002 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12112746     DOI: 10.1002/jms.324

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  3 in total

1.  Adduct Formation in ESI/MS by Mobile Phase Additives.

Authors:  Anneli Kruve; Karl Kaupmees
Journal:  J Am Soc Mass Spectrom       Date:  2017-03-15       Impact factor: 3.109

2.  Adduct formation in quantitative bioanalysis: effect of ionization conditions on paclitaxel.

Authors:  Kjell A Mortier; Guo-Fang Zhang; Carlos H van Peteghem; Willy E Lambert
Journal:  J Am Soc Mass Spectrom       Date:  2004-04       Impact factor: 3.109

3.  An improved method for measuring metaldehyde in surface water using liquid chromatography tandem mass spectrometry.

Authors:  Melanie Schumacher; Glenn Castle; Anthony Gravell; Graham A Mills; Gary R Fones
Journal:  MethodsX       Date:  2016-03-10
  3 in total