Literature DB >> 12112258

A simple algorithm improves mass accuracy to 50-100 ppm for delayed extraction linear matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

Christopher A Hack1, W Henry Benner.   

Abstract

A simple mathematical technique for improving mass calibration accuracy of linear delayed extraction matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (DE MALDI-TOFMS) spectra is presented. The method involves fitting a parabola to a plot of Delta(m) vs. mass data where Delta(m) is the difference between the theoretical mass of calibrants and the mass obtained from a linear relationship between the square root of m/z and ion time of flight. The quadratic equation that describes the parabola is then used to correct the mass of unknowns by subtracting the deviation predicted by the quadratic equation from measured data. By subtracting the value of the parabola at each mass from the calibrated data, the accuracy of mass data points can be improved by factors of 10 or more. This method produces highly similar results whether or not initial ion velocity is accounted for in the calibration equation; consequently, there is no need to depend on that uncertain parameter when using the quadratic correction. This method can be used to correct the internally calibrated masses of protein digest peaks. The effect of nitrocellulose as a matrix additive is also briefly discussed, and it is shown that using nitrocellulose as an additive to the alpha-cyano-4-hydroxycinnamic acid (alphaCHCA) matrix does not significantly change initial ion velocity but does change the average position of ions relative to the sample electrode at the instant the extraction voltage is applied. Published in 2002 by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12112258     DOI: 10.1002/rcm.715

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  3 in total

1.  Generation of CsI cluster ions for mass calibration in matrix-assisted laser desorption/ionization mass spectrometry.

Authors:  Xianwen Lou; Joost L J van Dongen; E W Meijer
Journal:  J Am Soc Mass Spectrom       Date:  2010-03-31       Impact factor: 3.109

2.  A constant-momentum/energy-selector time-of-flight mass spectrometer.

Authors:  C P Santacruz; P Håkansson; D F Barofsky; C K G Piyadasa
Journal:  J Am Soc Mass Spectrom       Date:  2006-10-06       Impact factor: 3.109

3.  Understanding the characteristics of mass spectrometry data through the use of simulation.

Authors:  Kevin R Coombes; John M Koomen; Keith A Baggerly; Jeffrey S Morris; Ryuji Kobayashi
Journal:  Cancer Inform       Date:  2005
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.