| Literature DB >> 12111936 |
Bruce M Damon1, Zhaohua Ding, Adam W Anderson, Andrea S Freyer, John C Gore.
Abstract
Diffusion-tensor (DT) MRI fiber tracking may potentially be used for in vivo structural analysis. The purpose of this study was to assess quantitatively the ability of a DT-MRI fiber-tracking algorithm to measure the fiber orientation (pennation) in skeletal muscle in vivo. In five adult Sprague-Dawley rats, the pennation angle (theta) was measured in the rat lateral gastrocnemius with DT-MRI (theta(DT-MRI)) and by direct anatomical inspection (DAI) (theta(DAI)). The mean theta(DT-MRI) was not significantly different from the mean theta(DAI). In addition, the two methods were highly correlated (r = 0.89) and the regression of theta(DT-MRI) on theta(DAI) resulted in a slope not significantly different from 1 and an intercept not significantly different from zero. These data indicate that DT-MRI-based fiber tracking as implemented here is a valid tool for in vivo structural analysis of small-animal skeletal muscle. Copyright 2002 Wiley-Liss, Inc.Entities:
Mesh:
Year: 2002 PMID: 12111936 DOI: 10.1002/mrm.10198
Source DB: PubMed Journal: Magn Reson Med ISSN: 0740-3194 Impact factor: 4.668