Literature DB >> 12111128

Low-dose dobutamine stress gated SPET for identification of viable myocardium: comparison with stress-rest perfusion SPET and PET.

Keiichiro Yoshinaga1, Chietsugu Katoh, Kazuyuki Noriyasu, Satoshi Yamada, Yoshinori Ito, Yuji Kuge, Yuko Kawai, Tetsuro Kohya, Akira Kitabatake, Nagara Tamaki.   

Abstract

The detection of viable myocardium is important for the prediction of functional recovery after revascularisation. However, a fixed perfusion defect often includes viable myocardium, and perfusion imaging then underestimates myocardial viability. We previously reported that low-dose dobutamine stress gated single-photon emission tomography (SPET) provides similar findings to dobutamine stress echocardiography in the assessment of myocardial viability. The present study investigated whether low-dose dobutamine stress gated SPET is of additional value as compared with stress-rest technetium-99m tetrofosmin SPET for the detection of myocardial viability. Standard stress-rest perfusion SPET, low-dose dobutamine stress gated SPET and fluorine-18 fluorodeoxyglucose positron emission tomography (FDG PET) were studied in 23 patients (mean age 67+/-7.6 years) with previous myocardial infarction. Twenty-one of them were successfully studied with each technique. FDG PET viability (FDG uptake >/=50%) was employed as the gold standard. One-day stress-rest (99m)Tc-tetrofosmin myocardial SPET was performed. After the resting study, gated SPET was acquired following infusion of 7.5 microg kg(-1) min(-1) of dobutamine. Left ventricular wall motion in 16 segments was assessed by cine mode display using a four-point scale. Myocardial viability was considered present when there was improvement by one point. Of a total of 336 segments analysed, 53 had persistent defects on stress-rest perfusion SPET. FDG viability was seen in 16 of 17 dobutamine-responsive segments, but in only 11 of 36 dobutamine non-responsive segments ( P<0.01). Thus, in the segments with persistent defects, viability findings on low-dose dobutamine stress gated SPET were concordant with those on FDG PET in 77% of segments (kappa value =0.55). For the detection of FDG-viable myocardium, the combination of stress-rest perfusion SPET and low-dose dobutamine stress gated SPET achieved a better sensitivity than stress-rest perfusion SPET alone (35/46, 76% vs 19/46, 41.3%, P<0.001), with a similar specificity (25/29, 86% vs 26/29, 90%, P=NS). We conclude that in the identification of viable myocardium, low-dose dobutamine stress gated SPET may provide additional information missed on a routine stress-rest perfusion scan. Dobutamine stress gated SPET may provide new insights into myocardial viability on the basis of ischaemia and contractile reserve.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12111128     DOI: 10.1007/s00259-002-0795-4

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  2 in total

1.  Positron emission tomography for the assessment of myocardial viability: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2005-10-01

2.  Exercise testing and myocardial perfusion scintigraphy in primary care patients with chest pain of new onset.

Authors:  Morten Scheike; Staffan Nilsson; Eva Nylander
Journal:  Scand J Prim Health Care       Date:  2007-06       Impact factor: 2.581

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.