| Literature DB >> 12110382 |
M G Quaglia1, E Donati, G Carlucci, P Mazzeo, S Fanali.
Abstract
Capillary Electrophoresis (CE) and Capillary Electrochromatography (CEC) have been used to determine losartan and hydrochlorothiazide. The CE separation was carried out in an uncoated capillary filled with a 100 mM sodium borate pH 9 solution containing trimethyl-beta-cyclodextrins. CEC was performed using a capillary packed with a RP-18 stationary phase. The mobile phase was a mixture of 50 mM ammonium acetate pH 7, water, acetonitrile (1/1.5/7.5). By CE and CEC suitable methods to determine simultaneously losartan and hydrochlorothiazide in working standard mixture or pharmaceutical form were obtained. The proposed methods are very simple and both gave accurate and precise results.Entities:
Mesh:
Substances:
Year: 2002 PMID: 12110382 DOI: 10.1016/s0731-7085(02)00138-3
Source DB: PubMed Journal: J Pharm Biomed Anal ISSN: 0731-7085 Impact factor: 3.935