Literature DB >> 12109846

Performance characteristics of four immunoassays for antiepileptic drugs on the IMMULITE 2000 automated analyzer.

Elizabeth L Frank1, Elisabeth L Schwarz, JoEtta Juenke, Thomas M Annesley, William L Roberts.   

Abstract

Carbamazepine, phenobarbital, phenytoin, and valproic acid are commonly used antiepileptic drugs that show complicated pharmacokinetic behavior Nonisotopic immunoassays are used routinely to monitor these drugs, and assay specificity is important to obtain accurate results. By using samples from subjects receiving each of these antiepileptic medications, competitive immunoassays for them were evaluated on an IMMULITE 2000 automated chemiluminescent analyzer (Diagnostic Products, Los Angeles, CA). Phenytoin assays were evaluated using an additional set of samples from patients with abnormal renal function. All 4 methods were linear, had imprecision of less than 10%, and compared well with other commercial immunoassays. A positive bias was observed for phenytoin measured in samples from uremic patients compared with a high-performance liquid chromatography reference method. The molar cross-reactivity of carbamazepine-10,11-epoxide was 12% in the carbamazepine assay. Phenytoin metabolites and fosphenytoin had substantial cross-reactivity in the phenytoin assay. All antiepileptic drug assays performed well and are suitable for use in monitoring patients receiving antiepileptic drug therapy. One possible exception is the phenytoin assay with samples from patients with renal insufficiency.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12109846     DOI: 10.1309/4502-68H7-1K1B-1JVR

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  4 in total

1.  Phenytoin immunoassay measurements in serum samples from patients with renal insufficiency: comparison with high-performance liquid chromatography.

Authors:  Maria J Tutor-Crespo; Jesús Hermida; J Carlos Tutor
Journal:  J Clin Lab Anal       Date:  2007       Impact factor: 2.352

2.  Immunoassay Methods and their Applications in Pharmaceutical Analysis: Basic Methodology and Recent Advances.

Authors:  Ibrahim A Darwish
Journal:  Int J Biomed Sci       Date:  2006-09

Review 3.  Utility, promise, and limitations of liquid chromatography-mass spectrometry-based therapeutic drug monitoring in precision medicine.

Authors:  Vanessa P Gaspar; Sahar Ibrahim; René P Zahedi; Christoph H Borchers
Journal:  J Mass Spectrom       Date:  2021-11-04       Impact factor: 1.982

Review 4.  Overview of therapeutic drug monitoring.

Authors:  Ju Seop Kang; Min Ho Lee
Journal:  Korean J Intern Med       Date:  2009-03       Impact factor: 3.165

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.