Literature DB >> 12108671

Rapid ion chromatography of L-ascorbic acid, nitrite, sulfite, oxalate, iodide and thiosulfate by isocratic elution utilizing a postcolumn reaction with cerium(IV) and fluorescence detection.

Yasuyuki Miura1, Masahide Hatakeyama, Thikara Hosino, Paul R Haddad.   

Abstract

Rapid separation and determination of mixtures of L-ascorbic acid, nitrite, sulfite, oxalate, iodide and thiosulfate by conventional ion chromatography is often difficult due to incomplete separation of L-ascorbic acid and nitrite from the water peak when using eluents giving short elution times for iodide and thiosulfate. Separation of the six species within about 15 min has been achieved by isocratic elution using a resin-based ion-exchange column with a carbonate eluent containing a trace amount of 1,3,5-benzenetricarboxylic acid (BTA) and fluorescence measurement of cerium(III) formed via postcolumn reactions of the separated sample species with cerium(IV). Calibration plots of peak height versus concentration were linear up to 10.0 microM (1.76 ppm) for L-ascorbic acid, 8.0 microM (0.37 ppm) for nitrite, 8.0 microM (0.70 ppm) for oxalate, 80.0 microM (10.2 ppm) for iodide and 25.0 microM (2.80 ppm) for thiosulfate, whilst the sulfite calibration was linear up to 25.0 microM (2.00 ppm) when peak area was plotted against concentration. Detection limits (defined as S/N = 3) were 18 ppb for L-ascorbic acid, 4 ppb for nitrite, 16 ppb for sulfite, 7 ppb for oxalate, 72 ppb for iodide and 37 ppb for thiosulfate. The proposed method was applied successfully to the determination of L-ascorbic acid, nitrite, sulfite, oxalate, iodide or thiosulfate in water samples.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12108671     DOI: 10.1016/s0021-9673(01)01497-2

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  Optimization of post-column reactor radius in capillary high performance liquid chromatography Effect of chromatographic column diameter and particle diameter.

Authors:  Hongjuan Xu; Stephen G Weber
Journal:  J Chromatogr A       Date:  2006-02-21       Impact factor: 4.759

2.  Biocompatible hydroxyapatite nanoparticles as a redox luminescence switch.

Authors:  Hongyan Liu; Pinxian Xi; Guoqiang Xie; Fengjuan Chen; Zhenpeng Li; Decheng Bai; Zhengzhi Zeng
Journal:  J Biol Inorg Chem       Date:  2011-07-19       Impact factor: 3.358

3.  A new fluorescent probe for colorimetric and ratiometric detection of sulfur dioxide derivatives in liver cancer cells.

Authors:  Dong-Peng Li; Zhao-Yang Wang; Jie Cui; Xin Wang; Jun-Ying Miao; Bao-Xiang Zhao
Journal:  Sci Rep       Date:  2017-03-28       Impact factor: 4.379

4.  The construction of a simple sensor for the simultaneous detection of nitrite and thiosulfate by heme catalysis.

Authors:  Guo-Cheng Han; Huifang Li; Annaleizle Ferranco; Yunyun Cheng; Zhencheng Chen; Mingyue Xue; Xiao-Zhen Feng; Heinz-Bernhard Kraatz
Journal:  RSC Adv       Date:  2020-09-22       Impact factor: 4.036

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.