Literature DB >> 12106731

Complications and clinical outcomes of intraocular lens exchange in patients with calcified hydrogel lenses.

Alexis K F Yu1, Anita S Y Ng.   

Abstract

PURPOSE: To evaluate the outcomes of intraocular lens (IOL) exchange in patients with calcified hydrogel IOLs.
SETTING: Ophthalmology departments of 2 university hospitals in Hong Kong, China.
METHODS: Fifteen patients developed loss of vision resulting from calcification of hydrogel IOLs. The calcified IOLs were explanted and replaced with new IOLs. The best corrected visual acuity before and after surgery was measured and compared.
RESULTS: The mean visual acuity was 0.03 (range 0.01 to 0.20) before IOL exchange and 0.20 (range 0.01 to 0.50) 3 months after; the difference was significant (P <.001). Acuity improved approximately 5 Snellen lines. Complications included posterior capsule rupture in 2 patients and zonular dehiscence in 3 patients; the secondary IOL was placed in the anterior chamber or ciliary sulcus in these patients. Three patients required cutting of the haptics before the calcified IOL could be removed.
CONCLUSION: Intraocular lens exchange was an effective treatment in patients with calcified hydrogel IOLs.

Entities:  

Mesh:

Year:  2002        PMID: 12106731     DOI: 10.1016/s0886-3350(02)01357-3

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  8 in total

1.  Investigation and management of an epidemic of Hydroview intraocular lens opacification.

Authors:  R W Altaie; T Costigan; S Donegan; P O'brien; U Mahmood; A J Bogdan; S Beatty
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-06-11       Impact factor: 3.117

2.  Surgical and visual outcomes following exchange of opacified Hydroview intraocular lenses.

Authors:  Rasha Altaie; Edward Loane; Kathleen O'Sullivan; Stephen Beatty
Journal:  Br J Ophthalmol       Date:  2006-10-31       Impact factor: 4.638

3.  Perioperative complications and clinical outcomes of intraocular lens exchange in patients with opacified lenses.

Authors:  Roberto Fernández-Buenaga; Jorge L Alió; Laura Pinilla-Cortés; Rafael I Barraquer
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-07-03       Impact factor: 3.117

4.  Intraocular Lens Fragmentation Using Femtosecond Laser: An In Vitro Study.

Authors:  Chandra Bala; Jeffrey Shi; Kerrie Meades
Journal:  Transl Vis Sci Technol       Date:  2015-06-11       Impact factor: 3.283

5.  Intraocular lens exchange through a 3.2-mm corneal incision for opacified intraocular lenses.

Authors:  Anil Kubaloglu; Esin Sogutlu Sari; Arif Koytak; Yasin Cinar; Kazim Erol; Yusuf Ozerturk
Journal:  Indian J Ophthalmol       Date:  2011 Jan-Feb       Impact factor: 1.848

6.  Late intraocular lens exchange in dissatisfied patients with multifocal intraocular lens implantation.

Authors:  Yu-Wei Kuo; Yu-Chih Hou
Journal:  Taiwan J Ophthalmol       Date:  2020-10-07

7.  Clinical efficacy and complications of intraocular lens exchange for opacified intraocular lenses.

Authors:  Seung Mo Kim; Sangkyung Choi
Journal:  Korean J Ophthalmol       Date:  2008-12

8.  Intraocular lens calcification;a clinicopathologic report.

Authors:  Mozhgan Rezaei-Kanavi; Mohammad-Ali Javadi; Firooz Mirbabaei-Ghafghazi
Journal:  J Ophthalmic Vis Res       Date:  2009-04
  8 in total