Literature DB >> 12106576

[Validation of two systems of self-measurement of blood pressure, the OMRON HEM-705 CP and OMRON M1 (HEM 422C2-E) models].

P Iglesias Bonilla1, E Mayoral Sánchez, J Lapetra Peralta, M Iborra Oquendo, F Villalba Alcalá, A Cayuela Domínguez.   

Abstract

Objective. To validate two monitors on the market for self-measurement of blood pressure (SMBP), an automatic one (OMRON HEM-705 CP) and a semi-automatic one (OMRON M1).Design. Descriptive study of validation of diagnostic tests.Setting. Primary care. San Pablo University Health Centre, Sevilla.Participants. 85 individuals (20 men and 65 women) with a wide range of age and blood pressure (BP), belonging to the population attended at the health centre or to its staff. People with arrhythmia and Korotkoff's V phase close to zero were excluded. Main measurements and results. BP and cardiac frequency (CF) measurements obtained with the SMBP devices to be validated were compared with readings on a mercury sphygmomanometer, used as the standard method. The differences between the SMBP devices and the gold standard were quantified and are presented on the scale proposed by the protocol of the British Hypertension Society (BHS). The mean (SD) of the systolic BP differences (in mm Hg) between the devices evaluated and the standard device was 1.084.73 for the automatic monitor and 1.255.30 for the semi-automatic one. The mean differences of diastolic BP were 0.444.03 for the automatic monitor, and 0.513.90 for the semi-automatic one. The cumulative percentage differences of systolic/ diastolic BP5, 10 and 15 mm Hg were 85.5, 98, 98.8/90.6, 98.4, 100% for the automatic monitor and 82.7, 95.7, 98.8/91, 99.6, 100% for the semi-automatic one. This supposes a Grade A on the BHS procedure, which is maintained on analysis of the results by blood pressure rankings. Conclusion. As both monitors meet the internationally accepted validation criteria, they can be recommended for the monitoring and self-monitoring of BP in patients with hypertension.

Entities:  

Mesh:

Year:  2002        PMID: 12106576     DOI: 10.1016/s0212-6567(02)78959-2

Source DB:  PubMed          Journal:  Aten Primaria        ISSN: 0212-6567            Impact factor:   1.137


  9 in total

Review 1.  Polyphenol intake from a Mediterranean diet decreases inflammatory biomarkers related to atherosclerosis: a substudy of the PREDIMED trial.

Authors:  Alexander Medina-Remón; Rosa Casas; Anna Tressserra-Rimbau; Emilio Ros; Miguel A Martínez-González; Montserrat Fitó; Dolores Corella; Jordi Salas-Salvadó; Rosa M Lamuela-Raventos; Ramón Estruch
Journal:  Br J Clin Pharmacol       Date:  2016-05-19       Impact factor: 4.335

2.  Spectral analyses of systolic blood pressure and heart rate variability and their association with cognitive performance in elderly hypertensive subjects.

Authors:  W B Santos; J M D Matoso; M Maltez; T Gonçalves; M Casanova; I F H Moreira; R A Lourenço; W D Monteiro; P T V Farinatti; P P Soares; W Oigman; M F T Neves; M L G Correia
Journal:  J Hum Hypertens       Date:  2014-12-18       Impact factor: 3.012

3.  The Effects of a Simulated Workday of Prolonged Sitting on Seated versus Supine Blood Pressure and Pulse Wave Velocity in Adults with Overweight/Obesity and Elevated Blood Pressure.

Authors:  Abdullah Bandar Alansare; Robert J Kowalsky; Melissa A Jones; Sophy J Perdomo; Lee Stoner; Bethany Barone Gibbs
Journal:  J Vasc Res       Date:  2020-09-16       Impact factor: 1.934

Review 4.  Determining which automatic digital blood pressure device performs adequately: a systematic review.

Authors:  Y Wan; C Heneghan; R Stevens; R J McManus; A Ward; R Perera; M Thompson; L Tarassenko; D Mant
Journal:  J Hum Hypertens       Date:  2010-04-08       Impact factor: 3.012

5.  The effect of numeracy level on completeness of home blood pressure monitoring.

Authors:  Vishal N Rao; Stacey L Sheridan; Laura A Tuttle; Feng-Chang Lin; Daichi Shimbo; Keith M Diaz; Alan L Hinderliter; Anthony J Viera
Journal:  J Clin Hypertens (Greenwich)       Date:  2014-11-29       Impact factor: 3.738

6.  Effect of the Mediterranean diet on blood pressure in the PREDIMED trial: results from a randomized controlled trial.

Authors:  Estefania Toledo; Frank B Hu; Ramon Estruch; Pilar Buil-Cosiales; Dolores Corella; Jordi Salas-Salvadó; M Isabel Covas; Fernando Arós; Enrique Gómez-Gracia; Miquel Fiol; Jose Lapetra; Luis Serra-Majem; Xavier Pinto; Rosa M Lamuela-Raventós; Guillermo Saez; Mònica Bulló; Valentina Ruiz-Gutiérrez; Emilio Ros; José V Sorli; Miguel Angel Martinez-Gonzalez
Journal:  BMC Med       Date:  2013-09-19       Impact factor: 8.775

7.  Visceral fat reduction is positively associated with blood pressure reduction in overweight or obese males but not females: an observational study.

Authors:  Xiaohui Guo; Yifan Xu; Hairong He; Hao Cai; Jianfen Zhang; Yibin Li; Xinyu Yan; Man Zhang; Na Zhang; Rolando L Maddela; Guansheng Ma
Journal:  Nutr Metab (Lond)       Date:  2019-07-10       Impact factor: 4.169

8.  Effects of Polyphenol, Measured by a Biomarker of Total Polyphenols in Urine, on Cardiovascular Risk Factors After a Long-Term Follow-Up in the PREDIMED Study.

Authors:  Xiaohui Guo; Anna Tresserra-Rimbau; Ramón Estruch; Miguel A Martínez-González; Alexander Medina-Remón; Olga Castañer; Dolores Corella; Jordi Salas-Salvadó; Rosa M Lamuela-Raventós
Journal:  Oxid Med Cell Longev       Date:  2016-01-04       Impact factor: 6.543

9.  Effects of a Meal Replacement on Body Composition and Metabolic Parameters among Subjects with Overweight or Obesity.

Authors:  Xiaohui Guo; Yifan Xu; Hairong He; Hao Cai; Jianfen Zhang; Yibin Li; Xinyu Yan; Man Zhang; Na Zhang; Rolando L Maddela; Jessie Nicodemus-Johnson; Guansheng Ma
Journal:  J Obes       Date:  2018-12-26
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.