Literature DB >> 12105357

Diagnostic accuracy of magnetic resonance angiography for cerebral aneurysms in correlation with 3D-digital subtraction angiographic images: a study of 133 aneurysms.

Mika Okahara1, Hiro Kiyosue, Masanori Yamashita, Hirohumi Nagatomi, Hiroyuki Hata, Toshiyuki Saginoya, Yoshiko Sagara, Hiromu Mori.   

Abstract

BACKGROUND AND
PURPOSE: We investigated the sensitivity of 3D-time-of flight (3D-TOF) magnetic resonance angiography (MRA) in the detection of cerebral aneurysms with the use of 3D digital subtraction angiography as the gold standard. We also evaluated the effects of location and number of aneurysms (and experience of the reader) on the sensitivity.
METHODS: 3D-TOF MRA was performed in 82 patients with 133 cerebral aneurysms. Each patient underwent rotational angiography. Three-dimensional reconstructed images were obtained from data of the rotational angiography (as the gold standard). A blind study with 4 readers of different experiences was performed to evaluate the diagnostic accuracy of 3D-TOF MRA for cerebral aneurysms.
RESULTS: One hundred five (79%) of all 133 aneurysms were detected with MRA by a neuroradiologist, 100 (75%) were detected by an experienced neurosurgeon, 84 (63%) were detected by a general radiologist, and 80 (60%) were detected by a resident neuroradiologist. For each reader, the detectability was lower for small aneurysms (<3 mm in maximum diameter) and/or for those located at the internal carotid artery and anterior cerebral artery. False-positive aneurysms were 29 for the neuroradiologist, 19 for the neurosurgeon, 31 for the general radiologist, and 30 for the resident neuroradiologist; most of the aneurysms were at the internal carotid artery. Causes of the false-positive and false-negative results included complex flow in a tortuous artery and susceptibility artifacts.
CONCLUSIONS: Although MRA is useful in the diagnosis of cerebral aneurysms, sufficient experience and careful attention are necessary for accurate diagnosis of aneurysms located at the internal carotid and anterior cerebral arteries.

Entities:  

Mesh:

Year:  2002        PMID: 12105357     DOI: 10.1161/01.str.0000019510.32145.a9

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  26 in total

1.  Evaluation of the lenticulostriate arteries with rotational angiography and 3D reconstruction.

Authors:  Hyun-Seung Kang; Moon Hee Han; Bae Ju Kwon; O-Ki Kwon; Sung Hyun Kim; Kee-Hyun Chang
Journal:  AJNR Am J Neuroradiol       Date:  2005-02       Impact factor: 3.825

2.  Differential diagnosis of the infundibular dilation and aneurysm of internal carotid artery: assessment with fusion imaging of 3D MR cisternography/angiography.

Authors:  T Satoh; M Omi; C Ohsako; K Fujiwara; K Tsuno; W Sasahara; K Onoda; K Tokunaga; K Sugiu; I Date
Journal:  AJNR Am J Neuroradiol       Date:  2006-02       Impact factor: 3.825

Review 3.  An approach to the patient with painful ophthalmoplegia, with a focus on Tolosa-Hunt syndrome.

Authors:  Jonathan P Gladstone
Journal:  Curr Pain Headache Rep       Date:  2007-08

4.  Follow-up of intracranial aneurysms treated with detachable coils: comparison of 3D inflow MRA at 3T and 1.5T and contrast-enhanced MRA at 3T with DSA.

Authors:  Birgitta Ramgren; Roger Siemund; Mats Cronqvist; Per Undrén; Ola G Nilsson; Stig Holtås; Elna-Marie Larsson
Journal:  Neuroradiology       Date:  2008-08-21       Impact factor: 2.804

5.  Composite MRA: statistical approach to generate an MR angiogram from multiple contrasts.

Authors:  Dahan Kim; Myriam Edjlali; Patrick Turski; Kevin M Johnson
Journal:  Magn Reson Med       Date:  2019-09-25       Impact factor: 4.668

6.  Evaluation of intracranial aneurysms with high-resolution MR angiography using single-artery highlighting technique: correlation with digital subtraction angiography.

Authors:  Hui Li; Lei Yan; Ming-Hua Li; Yong-Dong Li; Hua-Qiao Tan; Bin-Xian Gu; Wu Wang
Journal:  Radiol Med       Date:  2012-08-09       Impact factor: 3.469

7.  Angiographic CT with intravenous contrast injection compared with conventional rotational angiography in the diagnostic work-up of cerebral aneurysms.

Authors:  P Gölitz; T Struffert; F Knossalla; M Saake; S Ott; O Ganslandt; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2012-01-19       Impact factor: 3.825

8.  Prevalence of unruptured intracranial aneurysm on MR angiography.

Authors:  Tae Yeon Jeon; Pyoung Jeon; Keon Ha Kim
Journal:  Korean J Radiol       Date:  2011-08-24       Impact factor: 3.500

9.  Computer-aided diagnosis improves detection of small intracranial aneurysms on MRA in a clinical setting.

Authors:  I L Štepán-Buksakowska; J M Accurso; F E Diehn; J Huston; T J Kaufmann; P H Luetmer; C P Wood; X Yang; D J Blezek; R Carter; C Hagen; D Hořínek; A Hejčl; M Roček; B J Erickson
Journal:  AJNR Am J Neuroradiol       Date:  2014-06-12       Impact factor: 3.825

10.  Non-enhanced magnetic resonance imaging of unruptured intracranial aneurysms at 7 Tesla: Comparison with digital subtraction angiography.

Authors:  Karsten H Wrede; Toshinori Matsushige; Sophia L Goericke; Bixia Chen; Lale Umutlu; Harald H Quick; Mark E Ladd; Sören Johst; Michael Forsting; Ulrich Sure; Marc Schlamann
Journal:  Eur Radiol       Date:  2016-03-18       Impact factor: 5.315