Radiological protection for diagnostic examination of pregnant women.

Tomoko Kusama1, Katumasa Ota.   

Abstract

Application of diagnostic X-ray examination to pregnant women is complicated since risks to both mother and embryo/fetus must be considered. Embryos and fetuses are more sensitive to radiation than adults or children. The threshold doses for fetal death, malformations and mental retardation which are deterministic effects, are reported to be 100-200 mGy or higher. The relative risk for childhood cancer due to radiation at an absorbed dose of 10 mGy during embryonic/fetal development has been estimated at 1.4. However, the absorbed dose of the embryo/fetus during X-ray diagnostic examination in which the X-ray beam does not irradiate the embryo/fetus directly such as maternal skull and chest X-ray is extremely low, less than 0.01 mGy. Thus these diagnostic procedures are not a problem from the perspective of radiological protection of the embryo/fetus. However, for pelvic CT scan and barium enema in which the uterus is directly within the X-ray beam, the absorbed doses to the embryo/fetus are about 20-80 mGy and 10-20 mGy, respectively. Therefore, medical staff must pay careful attention to the embryo/fetus in application of these examinations. Pregnant women who were not aware of pregnancy at the time of their diagnostic exposure have great anxiety about radiation from such X-ray examinations. However, fetal doses below 100 mGy should not be considered a reason for terminating a pregnancy.

Entities:  

Mesh:

Year:  2002        PMID: 12094074     DOI: 10.1111/j.1741-4520.2002.tb00848.x

Source DB:  PubMed          Journal:  Congenit Anom (Kyoto)        ISSN: 0914-3505            Impact factor:   1.409


  8 in total

1.  Combined head and abdominal computed tomography for blunt trauma: which patients with minor head trauma benefit most?

Authors:  Sarah R Wu; Shamim Shakibai; John P McGahan; John R Richards
Journal:  Emerg Radiol       Date:  2006-08-30

2.  Imaging More Imagining less: An Insight into Knowledge, Attitude and Practice Regarding Radiation Risk on Pregnant Women among Dentists of Ghaziabad - A Cross Sectional Study.

Authors:  Monika Prasad; Ritu Gupta; Basavaraj Patthi; Ashish Singla; Venisha Pandita; Jishnu Krishna Kumar; Ravneet Malhi; Vaibhav Vashishtha
Journal:  J Clin Diagn Res       Date:  2016-07-01

3.  Development of computational pregnant female and fetus models and assessment of radiation dose from positron-emitting tracers.

Authors:  Tianwu Xie; Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-06-28       Impact factor: 9.236

Review 4.  Use of Positron Emission Tomography for Pregnancy-Associated Cancer Assessment: A Review.

Authors:  Giulia Parpinel; Maria Elena Laudani; Francesca Paola Giunta; Chiara Germano; Paolo Zola; Bianca Masturzo
Journal:  J Clin Med       Date:  2022-07-01       Impact factor: 4.964

5.  Diagnostic Dental Radiation Risk during Pregnancy: Awareness among General Dentists in Tabriz.

Authors:  Tahmineh Razi; Leila Bazvand; Morteza Ghojazadeh
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2011-06-14

Review 6.  CT evaluation of placental abruption in pregnant trauma patients.

Authors:  Sindy H Wei; Mohammad Helmy; Allen J Cohen
Journal:  Emerg Radiol       Date:  2009-03-11

7.  Coalition of attitude and practice behaviors among dental practitioners regarding pregnant patient's oral health and pregnant patient's perception toward oral health in and around Pondicherry.

Authors:  S Jeelani; K Abdul Khader; R Vishwanath Rangdhol; A Dany; Swetha Paulose
Journal:  J Pharm Bioallied Sci       Date:  2015-08

8.  Management of common bile duct stones in a pregnant woman by percutaneous biliary drainage followed by elective endoscopic stone removal after delivery.

Authors:  Komei Kambayashi; Masao Toki; Shunsuke Watanabe; Tadakazu Hisamatsu
Journal:  BMJ Case Rep       Date:  2022-03-23
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.