Literature DB >> 12093682

Performance of three microimmunofluorescence assays for detection of Chlamydia pneumoniae immunoglobulin M, G, and A antibodies.

Mette Bennedsen1, Lene Berthelsen, Inga Lind.   

Abstract

The microimmunofluorescence (MIF) test is considered the "gold standard" for laboratory diagnosis of acute and chronic Chlamydia pneumoniae infection. The performance of a MIF test based on C. pneumoniae antigen from Washington Research Foundation (WRF) was compared with those of assays from Labsystems (LAB) and MRL Diagnostics (MRL) by investigation of sera from three groups of patients: group I, 83 sera from 28 patients with atypical pneumonia; group II, 37 sera from 16 patients with acute C. pneumoniae or Chlamydia psittaci respiratory tract infection confirmed by PCR or culture; group III, 100 sera from 100 persons enrolled in the Copenhagen City Heart Study. The accordance among the results of the WRF assay and the two commercial assays was excellent for the immunoglobulin M (IgM) antibody detection rate (98%). The accordance in detection rates for IgG and IgA antibodies in sera from patients with acute infections was acceptable (87 and 88%), and in sera from group III, it was excellent (95 and 97%). The determinations of endpoint titers were reproducible with <1 dilution step difference for all three methods, except that the mean IgM antibody titer found by the LAB assay was almost 2 dilution steps higher than that found by the other two methods. Although the three assays use different C. pneumoniae strains as antigens, the detection rates and IgG and IgA endpoint titers were similar. The difference in endpoint titers of IgM antibodies is of no major concern, as the diagnosis of acute C. pneumoniae infection rests on the presence of IgM antibodies, not on their level.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12093682      PMCID: PMC120032          DOI: 10.1128/cdli.9.4.833-839.2002

Source DB:  PubMed          Journal:  Clin Diagn Lab Immunol        ISSN: 1071-412X


  16 in total

1.  Comparison of two commercial microimmunofluorescence kits and an enzyme immunoassay kit for detection of serum immunoglobulin G antibodies to Chlamydia pneumoniae.

Authors:  T O Messmer; J Martinez; F Hassouna; E R Zell; W Harris; S Dowell; G M Carlone
Journal:  Clin Diagn Lab Immunol       Date:  2001-05

2.  Chlamydia pneumoniae serology: interlaboratory variation in microimmunofluorescence assay results.

Authors:  R W Peeling; S P Wang; J T Grayston; F Blasi; J Boman; A Clad; H Freidank; C A Gaydos; J Gnarpe; T Hagiwara; R B Jones; J Orfila; K Persson; M Puolakkainen; P Saikku; J Schachter
Journal:  J Infect Dis       Date:  2000-06       Impact factor: 5.226

Review 3.  Standardizing Chlamydia pneumoniae assays: recommendations from the Centers for Disease Control and Prevention (USA) and the Laboratory Centre for Disease Control (Canada).

Authors:  S F Dowell; R W Peeling; J Boman; G M Carlone; B S Fields; J Guarner; M R Hammerschlag; L A Jackson; C C Kuo; M Maass; T O Messmer; D F Talkington; M L Tondella; S R Zaki
Journal:  Clin Infect Dis       Date:  2001-07-20       Impact factor: 9.079

4.  Serological evidence of an association of a novel Chlamydia, TWAR, with chronic coronary heart disease and acute myocardial infarction.

Authors:  P Saikku; M Leinonen; K Mattila; M R Ekman; M S Nieminen; P H Mäkelä; J K Huttunen; V Valtonen
Journal:  Lancet       Date:  1988-10-29       Impact factor: 79.321

5.  Evaluation of a new commercial microimmunofluorescence test for detection of antibodies to Chlamydia pneumoniae, Chlamydia trachomatis, and Chlamydia psittaci.

Authors:  H M Freidank; H Vögele; K Eckert
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1997-09       Impact factor: 3.267

Review 6.  Chlamydia pneumoniae, asthma, and COPD: what is the evidence?

Authors:  D L Hahn
Journal:  Ann Allergy Asthma Immunol       Date:  1999-10       Impact factor: 6.347

7.  The Copenhagen City Heart Study. Osterbroundersøgelsen. A book of tables with data from the first examination (1976-78) and a five year follow-up (1981-83). The Copenhagen City Heart Study Group.

Authors: 
Journal:  Scand J Soc Med Suppl       Date:  1989

8.  Immunologic relationship between genital TRIC, lymphogranuloma venereum, and related organisms in a new microtiter indirect immunofluorescence test.

Authors:  S P Wang; J T Grayston
Journal:  Am J Ophthalmol       Date:  1970-09       Impact factor: 5.258

9.  A polymerase chain reaction (PCR) protocol for the specific detection of Chlamydia spp.

Authors:  D R Pollard; S D Tyler; C W Ng; K R Rozee
Journal:  Mol Cell Probes       Date:  1989-12       Impact factor: 2.365

Review 10.  A new respiratory tract pathogen: Chlamydia pneumoniae strain TWAR.

Authors:  J T Grayston; L A Campbell; C C Kuo; C H Mordhorst; P Saikku; D H Thom; S P Wang
Journal:  J Infect Dis       Date:  1990-04       Impact factor: 5.226

View more
  6 in total

1.  Interlaboratory reliability of microimmunofluorescence test for measurement of Chlamydia pneumoniae-specific immunoglobulin A and G antibody titers.

Authors:  Alyson J Littman; Lisa A Jackson; Emily White; Mark D Thornquist; Charlotte A Gaydos; Thomas L Vaughan
Journal:  Clin Diagn Lab Immunol       Date:  2004-05

2.  Serodiagnosis of Chlamydia pneumoniae infection using three inclusion membrane proteins.

Authors:  Chen Hongliang; Zhou Zhou; Hu Zhan; Zeng Yanhua; Li Zhongyu; Lin Yingbiao; Dai Guozhi; Wu Yimou
Journal:  J Clin Lab Anal       Date:  2010       Impact factor: 2.352

3.  Randomised placebo controlled multicentre trial to assess short term clarithromycin for patients with stable coronary heart disease: CLARICOR trial.

Authors:  Christian M Jespersen; Bodil Als-Nielsen; Morten Damgaard; Jørgen Fischer Hansen; Stig Hansen; Olav H Helø; Per Hildebrandt; Jørgen Hilden; Gorm B Jensen; Jens Kastrup; Hans Jørn Kolmos; Erik Kjøller; Inga Lind; Henrik Nielsen; Lars Petersen; Christian Gluud
Journal:  BMJ       Date:  2005-12-08

4.  Comparison of quantitative and semiquantitative enzyme-linked immunosorbent assays for immunoglobulin G against Chlamydophila pneumoniae to a microimmunofluorescence test for use with patients with respiratory tract infections.

Authors:  Corinna Hermann; Katja Gueinzius; Albrecht Oehme; Sonja Von Aulock; Eberhard Straube; Thomas Hartung
Journal:  J Clin Microbiol       Date:  2004-06       Impact factor: 5.948

5.  Measurement of Chlamydia pneumoniae-specific immunoglobulin A (IgA) antibodies by the microimmunofluorescence (MIF) method: comparison of seven fluorescein-labeled anti-human IgA conjugates in an in-house MIF test using one commercial MIF and one enzyme immunoassay kit.

Authors:  Mika Paldanius; Aini Bloigu; Maija Leinonen; Pekka Saikku
Journal:  Clin Diagn Lab Immunol       Date:  2003-01

6.  Evaluation and optimization of a commercial enzyme linked immunosorbent assay for detection of Chlamydophila pneumoniae IgA antibodies.

Authors:  Olfa Frikha-Gargouri; Radhouane Gdoura; Abir Znazen; Nozha Ben Arab; Jalel Gargouri; Mounir Ben Jemaa; Adnene Hammami
Journal:  BMC Infect Dis       Date:  2008-07-26       Impact factor: 3.090

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.