Literature DB >> 12089124

Two administration methods for inhaled salbutamol in intubated patients.

S S Garner1, D B Wiest, J W Bradley, D M Habib.   

Abstract

AIMS: To compare serum concentrations and effects on respiratory mechanics and haemodynamics of salbutamol administered by small volume nebuliser (SVN) and metered dose inhaler (MDI) plus spacer.
METHODS: Blinded, randomised, crossover study in 12 intubated infants and children (mean age 17.8 months) receiving inhaled salbutamol therapy. Subjects received salbutamol as 0.15 mg/kg by SVN and four puffs (400 microg) by MDI plus spacer at a four hour interval in random order. Passive respiratory mechanics were measured by a single breath/single occlusion technique, and serum salbutamol concentrations by liquid chromatography-mass spectrometry at 30 minutes, 1, 2, and 4 hours after each dose. Haemodynamics (heart rate and blood pressure) were recorded at each measurement time.
RESULTS: There was no difference in percentage change in respiratory mechanics or haemodynamics between the two methods of administration. Mean area under the curve (AUC(0-4)) was 5.86 for MDI plus spacer versus 4.93 ng/ml x h for SVN.
CONCLUSIONS: Serum concentrations and effects on respiratory mechanics and haemodynamics of salbutamol were comparable with the two administration methods under the conditions studied. Future studies are needed to determine the most effective and safe combination of dose and administration method of inhaled salbutamol in mechanically ventilated infants and children.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12089124      PMCID: PMC1751136          DOI: 10.1136/adc.87.1.49

Source DB:  PubMed          Journal:  Arch Dis Child        ISSN: 0003-9888            Impact factor:   3.791


  33 in total

1.  Pulmonary mechanics in healthy term neonates: variability in measurements obtained with a computerized system.

Authors:  S K Gupta; J S Wagener; A Erenberg
Journal:  J Pediatr       Date:  1990-10       Impact factor: 4.406

2.  Effect of helium-oxygen on delivery of albuterol in a pediatric, volume-cycled, ventilated lung model.

Authors:  D M Habib; S S Garner; S Brandeburg
Journal:  Pharmacotherapy       Date:  1999-02       Impact factor: 4.705

3.  Effect of bronchodilators on airway resistance in ventilator-dependent neonates with chronic lung disease.

Authors:  R A Wilkie; M H Bryan
Journal:  J Pediatr       Date:  1987-08       Impact factor: 4.406

4.  Pulmonary mechanics during the first year of life.

Authors:  H Ahlström; B Jonson
Journal:  Scand J Respir Dis       Date:  1974

5.  A program package for simulation and parameter estimation in pharmacokinetic systems.

Authors:  D Z D'Argenio; A Schumitzky
Journal:  Comput Programs Biomed       Date:  1979-03

6.  Contaminated medication nebulizers in mechanical ventilator circuits. Source of bacterial aerosols.

Authors:  D E Craven; D A Lichtenberg; T A Goularte; B J Make; W R McCabe
Journal:  Am J Med       Date:  1984-11       Impact factor: 4.965

7.  Pressurized aerosol versus jet aerosol delivery to mechanically ventilated patients. Comparison of dose to the lungs.

Authors:  H D Fuller; M B Dolovich; G Posmituck; W W Pack; M T Newhouse
Journal:  Am Rev Respir Dis       Date:  1990-02

8.  Cost-benefit comparison of aerosol bronchodilator delivery methods in hospitalized patients.

Authors:  A C Jasper; Z Mohsenifar; S Kahan; H S Goldberg; S K Koerner
Journal:  Chest       Date:  1987-04       Impact factor: 9.410

9.  Passive respiratory mechanics in newborns and children.

Authors:  P N Lesouef; S J England; A C Bryan
Journal:  Am Rev Respir Dis       Date:  1984-04

10.  Increased compliance in response to salbutamol in premature infants with developing bronchopulmonary dysplasia.

Authors:  A Rotschild; A Solimano; M Puterman; J Smyth; A Sharma; S Albersheim
Journal:  J Pediatr       Date:  1989-12       Impact factor: 4.406

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.