Literature DB >> 12088450

Continuous wristband monitoring over 2 years decreases identification errors: a College of American Pathologists Q-Tracks Study.

Peter J Howanitz1, Stephen W Renner, Molly K Walsh.   

Abstract

CONTEXT: Identification of patients is one of the first steps in ensuring the accuracy of laboratory results. In the United States, hospitalized patients wear wristbands to aid in their identification, but wristbands errors are frequently found.
OBJECTIVE: To investigate if continuous monitoring of wristband errors by participants of the College of American Pathologists (CAP) Q-Tracks program results in lower wristband error rates.
SETTING: A total of 217 institutions voluntarily participating in the CAP Q-Tracks interlaboratory quality improvement program in 1999 and 2000.
DESIGN: Participants completed a demographic form, answered a questionnaire, collected wristband data, and at the end of the year, best and most improved performers answered another questionnaire seeking suggestions for improvement. Each institution's phlebotomists inspected wristbands for errors before performing phlebotomy and recorded the number of patients with wristband errors. On a monthly basis, participants submitted data to the CAP for data processing, and at the end of each quarter, participants received summarized comparisons. At the end of each year, participants also received a critique of the results along with suggestions for improvement. MAIN OUTCOME MEASURES: The percentage of wristband errors by quarter, types of wristband errors, and suggestions for improvement.
RESULTS: During 2 years, 1 757 730 wristbands were examined, and 45 197 wristband errors were found. The participants' mean wristband error rate for the first quarter in 1999 was 7.40%; by the eighth quarter, the mean wristband error rate had fallen to 3.05% (P <.001). Continuous improvement occurred in each quarter for participants in the 1999 and 2000 program and in 7 of 8 quarters for those who participated in both 1999 and 2000. Missing wristbands accounted for 71.6% of wristband errors, and best performers usually had wristband error rates under 1.0%. The suggestion for improvement provided by the largest number of best and most improved performers was that phlebotomists should refuse to perform phlebotomy on a patient when a wristband error is detected.
CONCLUSIONS: The wristband error rate decreased markedly when this rate was monitored continuously using the CAP Q-Tracks program. The Q-Tracks program provides a useful tool for improving the quality of services in anatomic pathology and laboratory medicine.

Entities:  

Mesh:

Year:  2002        PMID: 12088450     DOI: 10.5858/2002-126-0809-CWMOYD

Source DB:  PubMed          Journal:  Arch Pathol Lab Med        ISSN: 0003-9985            Impact factor:   5.534


  9 in total

Review 1.  Effectiveness of barcoding for reducing patient specimen and laboratory testing identification errors: a Laboratory Medicine Best Practices systematic review and meta-analysis.

Authors:  Susan R Snyder; Alessandra M Favoretto; James H Derzon; Robert H Christenson; Stephen E Kahn; Colleen S Shaw; Rich Ann Baetz; Diana Mass; Corinne R Fantz; Stephen S Raab; Milenko J Tanasijevic; Edward B Liebow
Journal:  Clin Biochem       Date:  2012-06-28       Impact factor: 3.281

2.  Identifying patients in hospital: are more adverse events waiting to happen?

Authors:  D C Perry; S J Scott
Journal:  Qual Saf Health Care       Date:  2007-04

3.  Use of identification wristbands among patients receiving inpatient treatment in a teaching hospital.

Authors:  Louíse Viecili Hoffmeister; Gisela Maria Schebella Souto de Moura
Journal:  Rev Lat Am Enfermagem       Date:  2015 Jan-Feb

Review 4.  Managing the pre- and post-analytical phases of the total testing process.

Authors:  Robert Hawkins
Journal:  Ann Lab Med       Date:  2011-12-20       Impact factor: 3.464

5.  Acceptability of identification bracelets for hospital inpatients.

Authors:  A Cleopas; V Kolly; P A Bovier; P Garnerin; T V Perneger
Journal:  Qual Saf Health Care       Date:  2004-10

6.  The Efficacy of Patients' Wristband Bar-code on Prevention of Medical Errors: A Meta-analysis Study.

Authors:  M Khammarnia; A Kassani; M Eslahi
Journal:  Appl Clin Inform       Date:  2015-12-09       Impact factor: 2.342

7.  Effectiveness of Laboratory Practices to Reducing Patient Misidentification Due to Specimen Labeling Errors at the Time of Specimen Collection in Healthcare Settings: LMBP™ Systematic Review.

Authors:  Paramjit Sandhu; Kakali Bandyopadhyay; Dennis J Ernst; William Hunt; Thomas H Taylor; Rebecca Birch; John Krolak; Sharon Geaghan
Journal:  J Appl Lab Med       Date:  2017-09

8.  Clinical Study of Using Biometrics to Identify Patient and Procedure.

Authors:  Jason W Sohn; Haksoo Kim; Samuel B Park; Soyoung Lee; James I Monroe; Thomas B Malone; Timothy Kinsella; Min Yao; Charles Kunos; Simon S Lo; Robert Shenk; Mitchell Machtay
Journal:  Front Oncol       Date:  2020-12-01       Impact factor: 6.244

Review 9.  How to conduct External Quality Assessment Schemes for the pre-analytical phase?

Authors:  Gunn B B Kristensen; Kristin Moberg Aakre; Ann Helen Kristoffersen; Sverre Sandberg
Journal:  Biochem Med (Zagreb)       Date:  2014-02-15       Impact factor: 2.313

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.