Literature DB >> 12088316

A new device for stereotactic CT-guided biopsy of the canine brain: design, construction, and needle placement accuracy.

Alain Giroux1, Jeryl C Jones, Jan Helge Bøhn, Robert B Duncan, Don R Waldron, Karen R Inzana.   

Abstract

An inexpensive device was created for computed tomographic (CT)-guided stereotactic biopsy of the canine brain. The accuracy of the device was tested using 16, formalin-perfused, canine head specimens. For each dog, a 6-inch biopsy needle was guided into pituitary gland and caudate nucleus targets. Needle tracks were measured using the CT computer and infused with tissue staining solution. Hit success and actual needle track lengths were determined from sliced brain specimens. The device enabled accurate orientation and placement of the canine head in the slice plane, such that progressive penetration of the biopsy needle could be monitored. The caudate nucleus was hit 12/16 times (75% accuracy) and the pituitary gland 15.5/16 times (98.6% accuracy). Hit proportions for the two targets did not differ (P < 0.05). A significant difference was found between CT and actual track length for both targets (P < 0.01). This was attributed to incomplete staining of the bevel portion of the needle track.

Entities:  

Mesh:

Year:  2002        PMID: 12088316     DOI: 10.1111/j.1740-8261.2002.tb00995.x

Source DB:  PubMed          Journal:  Vet Radiol Ultrasound        ISSN: 1058-8183            Impact factor:   1.363


  6 in total

Review 1.  Invited review--neuroimaging response assessment criteria for brain tumors in veterinary patients.

Authors:  John H Rossmeisl; Paulo A Garcia; Gregory B Daniel; John Daniel Bourland; Waldemar Debinski; Nikolaos Dervisis; Shawna Klahn
Journal:  Vet Radiol Ultrasound       Date:  2013-11-13       Impact factor: 1.363

2.  Accurate external localization of the left frontal cortex in dogs by using pointer based frameless neuronavigation.

Authors:  Robrecht Dockx; Kathelijne Peremans; Romain Duprat; Lise Vlerick; Nick Van Laeken; Jimmy H Saunders; Ingeborgh Polis; Filip De Vos; Chris Baeken
Journal:  PeerJ       Date:  2017-07-10       Impact factor: 2.984

3.  Feasability of a Frameless Brain Biopsy System for Companion Animals Using Cone-Beam CT-Based Automated Registration.

Authors:  Felix Meneses; Arianna Maiolini; Franck Forterre; Anna Oevermann; Daniela Schweizer-Gorgas
Journal:  Front Vet Sci       Date:  2022-02-09

4.  Computed Tomography-Guided Fine Needle Biopsies of Vertebral and Paravertebral Lesions in Small Animals.

Authors:  Patricia Laborda-Vidal; Myriam Martín; Marc Orts-Porcar; Laura Vilalta; Antonio Melendez-Lazo; Alejandra García de Carellán; Carlos Ros
Journal:  Animals (Basel)       Date:  2022-06-30       Impact factor: 3.231

5.  Frame-Based Stereotactic Biopsy of Canine Brain Masses: Technique and Clinical Results in 26 Cases.

Authors:  John Henry Rossmeisl; Rudy T Andriani; Thomas E Cecere; Kevin Lahmers; Tanya LeRoith; Kurt L Zimmerman; Denise Gibo; Waldemar Debinski
Journal:  Front Vet Sci       Date:  2015-07-27

6.  Accuracy of a magnetic resonance imaging-based 3D printed stereotactic brain biopsy device in dogs.

Authors:  Sarah Gutmann; Dirk Winkler; Marcel Müller; Robert Möbius; Jean-Pierre Fischer; Peter Böttcher; Ingmar Kiefer; Ronny Grunert; Thomas Flegel
Journal:  J Vet Intern Med       Date:  2020-02-24       Impact factor: 3.333

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.