Literature DB >> 12087226

Treatment of mandible fractures using bioabsorbable plates.

Young-Kyun Kim1, Su-Gwan Kim.   

Abstract

This study evaluated the short-term outcome of treating fractures of the mandible with bioabsorbable plates. Sixty-nine fractures of the mandible in 49 patients were treated by open reduction and internal fixation using bioabsorbable plates and 2.4-mm, 2.0-mm, and 1.5-mm pretapped screws. The duration of intermaxillary fixation ranged from 0 to 23 days, with a mean of 4.6 days. Patients were evaluated for complications during the follow-up period, which ranged from 1 to 18 months. Six patients (12.2 percent) experienced complications. These included infection (four patients), premature occlusal contact (one patient), and temporomandibular disorder (one patient). Except for one case, all complications were minor and adequately managed with incision and drainage, elastic traction, physical therapy, and medication. Delayed infection (osteomyelitis) developed in a symphysis fracture and was treated by saucerization and antibiotics. The fracture line subsequently showed complete consolidation. Bioabsorbable plates can be selectively used for internal fixation in mandibular fractures, with the advantage that they do not need to be removed.

Entities:  

Mesh:

Year:  2002        PMID: 12087226     DOI: 10.1097/00006534-200207000-00006

Source DB:  PubMed          Journal:  Plast Reconstr Surg        ISSN: 0032-1052            Impact factor:   4.730


  6 in total

1.  Choice of internal rigid fixation materials in the treatment of facial fractures.

Authors:  Mirko S Gilardino; Elliot Chen; Scott P Bartlett
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2009-03

2.  Bio-resorbable plates as effective implant in paediatric mandibular fracture.

Authors:  Geeta Singh; Shadab Mohammad; R K Chak; Norden Lepcha; Nimisha Singh; Laxman R Malkunje
Journal:  J Maxillofac Oral Surg       Date:  2011-12-28

3.  Early Experience with Biodegradable Fixation of Pediatric Mandibular Fractures.

Authors:  Ahmed Salah Mazeed; Mohammed Abdel-Raheem Shoeib; Samia Mohammed Ahmed Saied; Ahmed Elsherbiny
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2014-12-23

4.  Comparison of resorbable plates and titanium plates for fixation stability of combined mandibular symphysis and angle fractures.

Authors:  Ho-Yong Lim; Chang-Hwa Jung; Seong-Yong Kim; Jin-Yong Cho; Jae-Young Ryu; Hyeon-Min Kim
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2014-12-26

Review 5.  Hardware Removal in Craniomaxillofacial Trauma: A Systematic Review of the Literature and Management Algorithm.

Authors:  Thomas J Cahill; Rikesh Gandhi; Alexander C Allori; Jeffrey R Marcus; David Powers; Detlev Erdmann; Scott T Hollenbeck; Howard Levinson
Journal:  Ann Plast Surg       Date:  2015-11       Impact factor: 1.539

6.  Resorbable Implants for Mandibular Fracture Fixation: A Systematic Review and Meta-Analysis.

Authors:  Yehuda Chocron; Alain J Azzi; Sabrina Cugno
Journal:  Plast Reconstr Surg Glob Open       Date:  2019-08-30
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.