Literature DB >> 12085133

Ergonomic aspects of four different types of laparoscopic instrument handles with respect to elbow angle. An electromyogram-based study.

U Matern1, C Giebmeyer, R Bergmann, P Waller, M Faist.   

Abstract

BACKGROUND: Only few studies have tested different ergonomic aspects of the working posture assumed by laparoscopic surgeons. Although no experimental data are available for a laparoscopic setting, a working posture with a horizontal forearm or an elbow angle 90 degrees to 120 degrees has been recommended for performing minimally invasive surgery (MIS). The comparison of electromyogram (EMG) activities in different muscles provides information about the force developed by each muscle and allows assessment of its contribution to a functional movement. The current study aimed to investigate whether certain handles do not support this posture.
METHODS: For this study, 12 volunteers were postured in two different standardized arm positions, defined by elbow angles of 90 degrees and 120 degrees. They were manipulating a 0.1-N and a 2.5-N microswitch with four different types of instrument handle design: axial handle, ring handle, shank handle, Hirschberg handle. During the test, the EMG activities of five forearm muscles were recorded and normalized with respect to the maximum voluntary activity of the respective muscle.
RESULTS: Virtually no significant difference in EMG activity was found between the two elbow angles in any of five forearm muscles for a simple grasping maneuver. Thus, the muscle activity required to manipulate different types of MIS handles is similar for the elbow angles of 120 degrees and 90 degrees.
CONCLUSIONS: The current study did not show relevant differences between the two elbow angles for any of the four handles during a simple grasping maneuver with respect to the force required in the main forearm muscles.

Entities:  

Mesh:

Year:  2002        PMID: 12085133     DOI: 10.1007/s00464-001-9157-8

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  6 in total

1.  Ergonomic aspects of five different types of laparoscopic instrument handles under dynamic conditions with respect to specific laparoscopic tasks: an electromyographic-based study.

Authors:  U Matern; G Kuttler; C Giebmeyer; P Waller; M Faist
Journal:  Surg Endosc       Date:  2004-06-23       Impact factor: 4.584

2.  Ergonomic testing of two different types of handles via virtual reality simulation.

Authors:  U Matern; S Koneczny; M Tedeus; K Dietz; G Buess
Journal:  Surg Endosc       Date:  2005-04-28       Impact factor: 4.584

3.  Ergonomics of disposable handles for minimally invasive surgery.

Authors:  D Büchel; R Mårvik; B Hallabrin; U Matern
Journal:  Surg Endosc       Date:  2009-10-29       Impact factor: 4.584

4.  Effect of a laparoscopic instrument with rotatable handle piece on biomechanical stress during laparoscopic procedures.

Authors:  Benjamin Steinhilber; Robert Seibt; Florian Reiff; Monika A Rieger; Bernhard Kraemer; Ralf Rothmund
Journal:  Surg Endosc       Date:  2015-04-01       Impact factor: 4.584

5.  Socio-Technical Systems Analysis in Health Care: A Research Agenda.

Authors:  Pascale Carayon; Ellen Bass; Tommaso Bellandi; Ayse Gurses; Susan Hallbeck; Vanina Mollo
Journal:  IIE Trans Healthc Syst Eng       Date:  2011-12-02

Review 6.  Surgeon symptoms, strain, and selections: Systematic review and meta-analysis of surgical ergonomics.

Authors:  Chee-Chee H Stucky; Kate D Cromwell; Rachel K Voss; Yi-Ju Chiang; Karin Woodman; Jeffrey E Lee; Janice N Cormier
Journal:  Ann Med Surg (Lond)       Date:  2018-01-09
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.