Literature DB >> 12082498

Practice audits: reliability of sphygmomanometers and blood pressure recording bias.

S Ali1, A Rouse.   

Abstract

It is well established that numerous errors, biases and omissions in recording blood pressure exist. This study had two objectives. Firstly, to measure the accuracy of sphygmomanometers used in general practice and secondly to assess digit bias in blood pressure recording. This study was carried out in the then Northfield PCG, which comprised 18 practices and 67 GPs. A total of 131 mercury and aneroid sphygmomanometers were tested for accuracy by a trained technician in accordance with the methods specified in BS 2743 (1990). Accuracy was defined as an error of greater than 10 mm Hg. The second part of the methodology involved undertaking an audit of the proportion of registered patients aged 35-80 years who had their blood pressure measured within the last 5 years by members of the Primary Health Care Team. The results were that of the mercury and aneroid sphygmomanometers tested, 17% were inaccurate. Of these, 4% recorded an error greater than 10 mm Hg. One percent of mercury and 10% of aneroid sphygmomanometers recorded an error greater than 10 mm Hg respectively. Sixteen (12%) sphygmomanometers were so deteriorated (air leaks, dirt in mercury) that the researcher suggested their immediate withdrawal from service. The results of the blood pressure recording audit suggested digit bias of both systolic and diastolic recordings to the nearest 10 mm Hg. This study suggests that sphygmomanometers used in general practice are very likely to be inaccurate and some may well be so deteriorated that they should be withdrawn from service. The results of the blood pressure audit showed digit bias in systolic and diastolic readings to the nearest 10 mm Hg. The implications for clinical care-both over diagnosis and under diagnosis-although not assessed are likely to be appreciable. PCG Clinical Governance teams in conjunction with Practice Clinical Leads must address these basic issues.

Entities:  

Mesh:

Year:  2002        PMID: 12082498     DOI: 10.1038/sj.jhh.1001384

Source DB:  PubMed          Journal:  J Hum Hypertens        ISSN: 0950-9240            Impact factor:   3.012


  13 in total

1.  Clinical characteristics of HIV-infected patients with adjudicated heart failure.

Authors:  Alexandra B Steverson; Anna E Pawlowski; Daniel Schneider; Prasanth Nannapaneni; Jes M Sanders; Chad J Achenbach; Sanjiv J Shah; Donald M Lloyd-Jones; Matthew J Feinstein
Journal:  Eur J Prev Cardiol       Date:  2017-09-25       Impact factor: 7.804

2.  Differential Associations of Chronic Inflammatory Diseases With Incident Heart Failure.

Authors:  Sameer Prasada; Adovich Rivera; Arvind Nishtala; Anna E Pawlowski; Arjun Sinha; Joshua D Bundy; Simran A Chadha; Faraz S Ahmad; Sadiya S Khan; Chad Achenbach; Frank J Palella; Rosalind Ramsey-Goldman; Yvonne C Lee; Jonathan I Silverberg; Babafemi O Taiwo; Sanjiv J Shah; Donald M Lloyd-Jones; Matthew J Feinstein
Journal:  JACC Heart Fail       Date:  2020-04-08       Impact factor: 12.035

3.  How do family physicians measure blood pressure in routine clinical practice? National survey of Canadian family physicians.

Authors:  Janusz Kaczorowski; Martin G Myers; Mark Gelfer; Martin Dawes; Eric J Mang; Angelique Berg; Claudio Del Grande; Dragan Kljujic
Journal:  Can Fam Physician       Date:  2017-03       Impact factor: 3.275

4.  Zero end-digit preference in recorded blood pressure and its impact on classification of patients for pharmacologic management in primary care - PREDICT-CVD-6.

Authors:  Joanna Broad; Sue Wells; Roger Marshall; Rod Jackson
Journal:  Br J Gen Pract       Date:  2007-11       Impact factor: 5.386

5.  Development and Validation of a Hypertension Prevalence Estimator Tool For Use in Clinical Settings.

Authors:  Matthew Ritchey; Keming Yuan; Cathleen Gillespie; Guangyu Zhang; Yechiam Ostchega
Journal:  J Clin Hypertens (Greenwich)       Date:  2016-01-05       Impact factor: 3.738

6.  Beyond the Evidence of the New Hypertension Guidelines. Blood pressure measurement - is it good enough for accurate diagnosis of hypertension? Time might be in, for a paradigm shift (I).

Authors:  Cornel Pater
Journal:  Curr Control Trials Cardiovasc Med       Date:  2005-04-06

7.  The effect of an e-health intervention designed to reduce prolonged occupational sitting on mean arterial pressure.

Authors:  Casey P Mainsbridge; Paul D Cooley; Sharon P Fraser; Scott J Pedersen
Journal:  J Occup Environ Med       Date:  2014-11       Impact factor: 2.162

8.  Renal Denervation in a Real Life Setting: A Gradual Decrease in Home Blood Pressure.

Authors:  Martine M A Beeftink; Wilko Spiering; Michiel L Bots; Willemien L Verloop; Rosa L De Jager; Margreet F Sanders; Evert-Jan Vonken; Peter J Blankestijn; Michiel Voskuil
Journal:  PLoS One       Date:  2016-09-15       Impact factor: 3.240

Review 9.  Sources of inaccuracy in the measurement of adult patients' resting blood pressure in clinical settings: a systematic review.

Authors:  Noa Kallioinen; Andrew Hill; Mark S Horswill; Helen E Ward; Marcus O Watson
Journal:  J Hypertens       Date:  2017-03       Impact factor: 4.844

10.  Impact of terminal digit preference by family physicians and sphygmomanometer calibration errors on blood pressure value: implication for hypertension screening.

Authors:  Theophile Niyonsenga; Alain Vanasse; Josiane Courteau; Lyne Cloutier
Journal:  J Clin Hypertens (Greenwich)       Date:  2008-05       Impact factor: 3.738

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.