Literature DB >> 12080435

Renovascular disease in patients with hypertension: detection with duplex ultrasound.

M W de Haan1, A A Kroon, K Flobbe, A G H Kessels, J H Tordoir, J M A van Engelshoven, P W de Leeuw.   

Abstract

The aim of this study was to evaluate the accuracy of duplex ultrasound for the diagnosis of renovascular disease in a cohort of hypertensive patients. In 78 patients suspected of renovascular hypertension on clinical grounds duplex ultrasound examination of the renal arteries was performed. Renal angiography was used as the standard of reference. Duplex ultrasound was inconclusive in 11 kidneys (7%). None of the supernumerary renal arteries was detected with duplex ultrasound. The overall prevalence of significant renovascular disease (> or =50% stenosis) was 20%. Based on the combination of parameters at thresholds commonly applied in current literature: ie PSV(max) >180 cm/sec and RAR >3.5 the overall sensitivity of duplex ultrasound for detection of haemodynamically significant renovascular disease was 50.0% with a specificity of 91.3% (PPV: 87.9%; NPV: 59.1). Lowering the thresholds for both parameters improved the test results at the cost of a significant increase of false positive examinations. In a population of hypertensive patients clinically suspected of renovascular hypertension, only limited results for duplex ultrasound could be acquired in the detection of renovascular disease. This result, in combination with the wide range of sensitivities and specificities published in international literature and the relatively large number of incomplete examinations does not support the general application of duplex ultrasound as a screening procedure for detection and assessment of renovascular disease.

Entities:  

Mesh:

Year:  2002        PMID: 12080435     DOI: 10.1038/sj.jhh.1001429

Source DB:  PubMed          Journal:  J Hum Hypertens        ISSN: 0950-9240            Impact factor:   3.012


  3 in total

Review 1.  An update on renovascular hypertension.

Authors:  Martin Senitko; Andrew Z Fenves
Journal:  Curr Cardiol Rep       Date:  2005-11       Impact factor: 2.931

Review 2.  Contemporary imaging techniques for the diagnosis of renal artery stenosis.

Authors:  T Leiner; M W de Haan; P J Nelemans; J M A van Engelshoven; G B C Vasbinder
Journal:  Eur Radiol       Date:  2005-06-28       Impact factor: 5.315

3.  Role of color-Doppler sonography in the follow-up of renal artery stenting.

Authors:  G C Parenti; D Palmarini; M Bilzoni; P Campioni; P Mannella; A Ginevra
Journal:  Radiol Med       Date:  2008-04-02       Impact factor: 3.469

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.