Comparison of external jugular and central venous pressures in mechanically ventilated patient.

J L Parker1, C J R Flucker, N Harvey, A M Maguire, W C Russell, J P Thompson.   

Abstract

We compared central venous pressures, measured via a 150 mm triple lumen catheter in the internal jugular vein with simultaneous external jugular venous pressures, measured with a 5 mm cannula in the external jugular vein, in 24 patients undergoing major surgery. Patients were mechanically ventilated in the supine position. Six sets of paired measurements of mean central venous pressure and mean external jugular venous pressure were taken by a blinded observer, in random order and at end-expiration at 30-min intervals during surgery. Four patients were not studied because of a failure to cannulate the external jugular vein. The remaining 20 patients yielded 111 sets of paired measurements. The mean difference between external jugular venous pressure and central venous pressure was 0.3 mmHg over a range of central venous pressure of 0-22 mmHg. Limits of agreement were 3.6 to +3.0 mmHg (95% CI 4.1 to +3.5 mmHg). We conclude that external jugular venous pressure is an accurate estimate of central venous pressure in surgical patients undergoing mechanical ventilation.

Entities:  

Mesh:

Year:  2002        PMID: 12073949     DOI: 10.1046/j.1365-2044.2002.02509_4.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  3 in total

Review 1.  A case of left-sided absence and right-sided fenestration of the external jugular vein and a review of the literature.

Authors:  Erika Cvetko
Journal:  Surg Radiol Anat       Date:  2014-11-30       Impact factor: 1.246

2.  Positive end-expiratory pressure-induced increase in external jugular venous pressure does not predict fluid responsiveness in laparoscopic prostatectomy.

Authors:  Min Hur; Seokha Yoo; Jung-Yoon Choi; Sun-Kyung Park; Dhong Eun Jung; Won Ho Kim; Jin-Tae Kim; Jae-Hyon Bahk
Journal:  J Anesth       Date:  2018-02-27       Impact factor: 2.078

3.  The Sheep as a Comprehensive Animal Model to Investigate Interdependent Physiological Pressure Propagation and Multiparameter Influence on Cerebrospinal Fluid Dynamics.

Authors:  Nina Eva Trimmel; Anthony Podgoršak; Markus Florian Oertel; Simone Jucker; Margarete Arras; Marianne Schmid Daners; Miriam Weisskopf
Journal:  Front Neurosci       Date:  2022-03-31       Impact factor: 4.677

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.