Literature DB >> 12073573

[Antimicrobial effects and efficacy on habitually hand-washing of strong acidic electrolyzed water--a comparative study of alcoholic antiseptics and soap and tap water].

Mikako Sakashita1, Atsuo Iwasawa, Yoshiko Nakamura.   

Abstract

The rate of bacterial elimination for the stamp method was compared with regular hand-washing (using soap and tap water), hygienic hand-washing (using alcoholic antiseptics), and hand-washing using strong acidic electrolyzed water (the SAEW method) in routine work. After routine work, the average number of bacteria remaining on the nurse's hands with using the SAEW-method, rubbing method and tap water method, were: 54 +/- 63, 89 +/- 190, 128 +/- 194 CFU/agar plate, respectively (n = 81). In this study. It was clarified that a much larger number of Bacillus sp. were detected for the rubbing method than for the other methods. After further nurse work, the most number of absorbed bacteria on a nurse's hands were counted after cleaning a patient's body. The rate of bacteria elimination for hand-washing with soap and tap water after taking care of a patient was insufficient, especially when before care was provided the number of bacteria on the nurse's hands were less than 100 CFU/agar plate. From these results, the following manual for sanitary hand washing is recommended: 1. At first, dirty hands should be cleaned and the number of bacteria should be reduced using soap and tap water or by scrubbing with disinfectants. 2. After the number of bacteria has been reduced, use the SAEW method routinely. 3. For care requiring a high level of cleanliness or if no tap water facilities are available, use the rubbing method. Finally, routine use of the SAEW method in ICU could be recommended with conventional disinfectants and soap and tap water on a case by case basis for less than adverse reactions, such as in the case of rough-hands or keeping a low level of bacteria on hands.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12073573     DOI: 10.11150/kansenshogakuzasshi1970.76.373

Source DB:  PubMed          Journal:  Kansenshogaku Zasshi        ISSN: 0387-5911


  3 in total

Review 1.  Electrochemically activated solutions: evidence for antimicrobial efficacy and applications in healthcare environments.

Authors:  R M S Thorn; S W H Lee; G M Robinson; J Greenman; D M Reynolds
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2011-08-02       Impact factor: 3.267

2.  Evaluation of effect and comparison of superoxidised solution (oxum) v/s povidone iodine (betadine).

Authors:  Vanita Kapur; Anil Kumar Marwaha
Journal:  Indian J Surg       Date:  2010-12-16       Impact factor: 0.656

3.  Antibacterial activity and safety of commercial veterinary cationic steroid antibiotics and neutral superoxidized water.

Authors:  Benjamin E Bergstrom; Ahmed Abdelkhalek; Waleed Younis; G Kenitra Hammac; Wendy M Townsend; Mohamed N Seleem
Journal:  PLoS One       Date:  2018-03-07       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.