[Clinical indications for pacemaker exchange and functional studies of the explanted aggregates (author's transl)].

J Rivas-Martin, J A Herzer, G Irlich, H D Schulte, L Seipel.   

Abstract

For the purpose of examining the clinical exchange indication 96 removed Demand-pacemakers (type Medtronic 5842, 5843, 5942, 5943) had been sujected to a functional test by the manufacturers. After a service-life from 31-45 months 71% (i.e. 42 out of 59 units) and, in the group with a service-life from 31-35 months, 66% (i.e. 33 out of 51 units) of pacemaker units removed at that time were still working regularly. The mean energy loss exceeded 70% with a simultaneous mean drop of the output voltage down to 2.5 Volts. After the 25th month of the implantation date the number of battery failure increased spasmodically. Under the suspicion diagnosis of "battery exhaustion" a prophylactic "selective" exchange operation of the pace-maker units implied does not appear justifiable to us but in cases with stable AV-Block III. Providing reliable supervision of patients with sufficient self-rhythm, the exchange may be delayed up to about the 40th month after the implantation.

Entities:  

Mesh:

Year:  1975        PMID: 1207345     DOI: 10.1007/bf01259415

Source DB:  PubMed          Journal:  Langenbecks Arch Chir        ISSN: 0023-8236


  13 in total

Review 1.  [15 years of pacemaker therapy. Status and developmental trends].

Authors:  S Effert; W Irnich
Journal:  Dtsch Med Wochenschr       Date:  1974-05-24       Impact factor: 0.628

2.  Ten-year survey of treatment with implanted cardiac pacemaker.

Authors:  E Sowton; G Hendrix; P Roy
Journal:  Br Med J       Date:  1974-07-20

3.  [Advantages of programmable cardiac pacemakers].

Authors:  F W Hehrlein; J Mulch; P Pahutan; M Iida
Journal:  Thoraxchir Vask Chir       Date:  1973-06

4.  [Patient-orientated pacemaker control with the pace-guard system (author's transl)].

Authors:  A Wirtzfeld; M Lampadius; C Himmler
Journal:  Dtsch Med Wochenschr       Date:  1974-12-20       Impact factor: 0.628

5.  [Eperience with permanent pacemakers].

Authors:  V C Schmitt; O Zelder; M Fischer
Journal:  Zentralbl Chir       Date:  1974-11-29       Impact factor: 0.942

6.  Progress in pacemaker longevity.

Authors:  D Friedberg; R C Lillehei
Journal:  J Electrocardiol       Date:  1974-02       Impact factor: 1.438

7.  [Long-term therapy of atrioventricular block].

Authors:  F Loogen; I Buchta; W Krelhaus; L Seipel
Journal:  Z Gesamte Inn Med       Date:  1973-02-01

8.  [Changing indications of pacemaker therapy (author's transl)].

Authors:  P Doenecke; G Rettig; L Bette
Journal:  Dtsch Med Wochenschr       Date:  1973-12-07       Impact factor: 0.628

9.  [The use of nuclear-energy powered pacemakers for transvenous endocardial stimulation (author's transl)].

Authors:  K A Rosenkranz; M Schaldach
Journal:  Dtsch Med Wochenschr       Date:  1973-11-23       Impact factor: 0.628

10.  [Control of implanted pacemakers].

Authors:  W Irnich; S Effert
Journal:  Dtsch Med Wochenschr       Date:  1970-05-15       Impact factor: 0.628

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.