PURPOSE: To assess thermal effects of Q-switched Er:YAG laser trephination to corneal epithelium and superficial stroma using different mask types and materials for experimental penetrating keratoplasty.
METHODS: Laser trephination was performed in 20 freshly-enucleated porcine eyes (repetition rate 5 Hz, pulse energy 65 mJ, spot size 0.7 mm). We used flat, open-metal and ceramic masks for donor and recipient trephination placed directly onto the corneal surface. Main outcome measures as assessed by light microscopy after PAS staining of 8-microm paraffin sections included: extension of tissue thermal damage at the cut edge in the superficial and basal epithelial layers, the basement membrane and subepithelial stroma, and depth and width of epithelial/stromal involvement in the area of the donor mask contact.
RESULTS: The thermal damage in the superficial epithelium was more pronounced in donor (mean extension 61.6 +/- 15.6 microm) than in recipient (29.4 +/- 24.9 microm, p= 0.05) trephination. In donor trephination, thermal damage zone of the superficial epithelial layer was significantly smaller with ceramic than with metal masks (21.0 +/- 23.0 versus 61.6 +/- 15.6 microm, p= 0.014). In contrast, differences at basal epithelial layer (p= 0.44), basement membrane (p= 0.79), and subepithelial stroma (p= 0.2) were not statistically significant. Superficial donor involvement of the cornea adjacent to the paracentral donor mask contact zone was seen neither with ceramic nor with metal masks.
CONCLUSION: Superficial corneal alterations adjacent to the mask-cornea contact zone may be minimized by using the Er:YAG laser in a Q-switched mode. Ceramic masks, in contrast to metal masks, further reduce superficial thermal alterations at the cut edge.

Entities:  

Mesh:

Year:  2002        PMID: 12072726     DOI: 10.1097/00003226-200207000-00012

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  1 in total

1.  Corneal shrinkage induced by nonmechanical Q-switched erbium:YAG laser trephination for penetrating keratoplasty in porcine eyes.

Authors:  Milenko Stojkovic; Berthold Seitz; Michael Küchle; Achim Langenbucher; Arne Viestenz; Anja Viestenz; Carmen Hofmann-Rummelt; Gottfried O H Naumann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-07-17       Impact factor: 3.117

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.