Effects of a multifaceted, multidisciplinary, hospital-wide quality improvement program on weaning from mechanical ventilation.

Nicholas A Smyrnios1, Ann Connolly, Mark M Wilson, Frederick J Curley, Cynthia T French, Stephen O Heard, Richard S Irwin.   

Abstract

OBJECTIVE: To examine the effects of a mechanical ventilation weaning management protocol that was implemented as a hospital-wide, quality improvement program on clinical and economic outcomes.
DESIGN: Prospective, before-and-after intervention study. Data from a preimplementation year are compared with those of the first 2 yrs after protocol implementation. PATIENTS AND
SETTING: Patients older than 18 yrs in diagnosis-related group 475 and group 483, who were admitted to the adult medical, surgical, and cardiac intensive care units (ICU) in a university hospital.
INTERVENTIONS: After the baseline year, a weaning management program was implemented throughout our institution. Primary endpoints were mortality, days on mechanical ventilation, ICU and hospital lengths of stay, hospital costs, and the percentage of patients requiring tracheostomy. MAIN
RESULTS: The number of patients increased from 220 in the baseline year (year 0) to 247 in the first year (year 1), then to 267 in the second year (year 2). The mean Acute Physiology and Chronic Health Evaluation (APACHE) II score increased from 22.2 to 24.4 in year 1 (p =.006) and to 26.2 in year 2 (p <.0005). When year 0 was compared with year 1, mean days on mechanical ventilation decreased from 23.9 to 21.9 days (p =.608), hospital length of stay decreased from 37.5 to 31.6 days (p =.058), ICU length of stay decreased from 30.5 to 25.9 days (p =.133), and total cost per case decreased from $92,933 to $78,624 (p =.061). When year 0 was compared with year 2, mean days on mechanical ventilation decreased from 23.9 days to 17.5 days (p =.004), mean hospital length of stay decreased from 37.5 to 24.7 days, mean ICU length of stay decreased from 30.5 to 20.3 days, total cost per case decreased from $92,933 to $63,687, and percentage of patients requiring tracheotomy decreased from 61% to 41% (all p <.0005). There was also a reduction in the percentage of patients requiring more than one course of mechanical ventilation during the hospitalization from 33% to 26% (p =.039), a total cost savings of $3,440,787 and a decrease in mortality between all 3 yrs from 32% to 28% (p =.062).
CONCLUSIONS: A multifaceted, multidisciplinary weaning management program can change the process of care used for weaning patients from mechanical ventilation throughout an acute care hospital and across multiple services. This change can lead to large reductions in the duration of mechanical ventilation, length of stay, and hospital costs, even at a time when patients are sicker.

Entities:  

Mesh:

Year:  2002        PMID: 12072672     DOI: 10.1097/00003246-200206000-00009

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  12 in total

1.  A knowledge- and model-based system for automated weaning from mechanical ventilation: technical description and first clinical application.

Authors:  Dirk Schädler; Stefan Mersmann; Inéz Frerichs; Gunnar Elke; Thomas Semmel-Griebeler; Oliver Noll; Sven Pulletz; Günther Zick; Matthias David; Wolfgang Heinrichs; Jens Scholz; Norbert Weiler
Journal:  J Clin Monit Comput       Date:  2013-07-28       Impact factor: 2.502

2.  Effect of a quality improvement program on weaning from mechanical ventilation: a cluster randomized trial.

Authors:  Bo Zhu; Zhiqiang Li; Li Jiang; Bin Du; Qi Jiang; Meiping Wang; Ran Lou; Xiuming Xi
Journal:  Intensive Care Med       Date:  2015-07-09       Impact factor: 17.440

3.  The availability of clinical protocols in US teaching intensive care units.

Authors:  Meeta Prasad; Jason D Christie; Scarlett L Bellamy; Gordon D Rubenfeld; Jeremy M Kahn
Journal:  J Crit Care       Date:  2010-04-08       Impact factor: 3.425

Review 4.  Economics of ICU organization and management.

Authors:  Hannah Wunsch; Hayley Gershengorn; Damon C Scales
Journal:  Crit Care Clin       Date:  2011-10-22       Impact factor: 3.598

5.  Fluid balance and weaning outcomes.

Authors:  Anupama Upadya; Lisa Tilluckdharry; Visvanathan Muralidharan; Yaw Amoateng-Adjepong; Constantine A Manthous
Journal:  Intensive Care Med       Date:  2005-09-29       Impact factor: 17.440

6.  Chronic obstructive pulmonary disease and weaning of difficult-to-wean patients from mechanical ventilation: randomized prospective study.

Authors:  Ivo Matić; Davorin Danić; Visnja Majerić-Kogler; Matija Jurjević; Ivan Mirković; Natalija Mrzljak Vucinić
Journal:  Croat Med J       Date:  2007-02       Impact factor: 1.351

7.  Using Incentives to Improve Resource Utilization: A Quasi-Experimental Evaluation of an ICU Quality Improvement Program.

Authors:  David J Murphy; Peter F Lyu; Sara R Gregg; Greg S Martin; Jason M Hockenberry; Craig M Coopersmith; Michael Sterling; Timothy G Buchman; Jonathan Sevransky
Journal:  Crit Care Med       Date:  2016-01       Impact factor: 7.598

8.  Facilitators of an interprofessional approach to care in medical and mixed medical/surgical ICUs: a multicenter qualitative study.

Authors:  Deena Kelly Costa; Frances K Barg; David A Asch; Jeremy M Kahn
Journal:  Res Nurs Health       Date:  2014-07-03       Impact factor: 2.228

9.  Weaning children from mechanical ventilation with a computer-driven protocol: a pilot trial.

Authors:  Philippe A Jouvet; Valérie Payen; France Gauvin; Guillaume Emeriaud; Jacques Lacroix
Journal:  Intensive Care Med       Date:  2013-01-30       Impact factor: 17.440

10.  Automatic versus manual pressure support reduction in the weaning of post-operative patients: a randomised controlled trial.

Authors:  Corinne Taniguchi; Raquel C Eid; Cilene Saghabi; Rogério Souza; Eliezer Silva; Elias Knobel; Angela T Paes; Carmen S Barbas