Literature DB >> 12067876

Cricoid pressure decreases ease of tracheal intubation using fibreoptic laryngoscopy (WuScope System.

Charles E Smith1, Donald Boyer.   

Abstract

PURPOSE: Cricoid pressure is commonly used during rapid sequence induction and intubation to minimize the risk of aspiration. The objective of the study was to evaluate the ease of fibreoptic (WuScope System(TM)) intubation in anesthetized adults receiving cricoid pressure.
METHODS: The intubation difficulty scale (IDS) was used to measure tracheal intubation difficulties in 33 patients undergoing elective surgery with general anesthesia and complete neuromuscular blockade. Each patient had their trachea intubated under two conditions: with and without cricoid pressure. The order of conditions was determined randomly. Cricoid pressure was applied by an experienced anesthesia provider. MAIN
RESULTS: An IDS value of 0 (ideal intubation, that is one performed by the first operator on the first attempt, using the first technique with full visualization of the glottis and no vocal cord compression) occurred in 30 of 33 patients (91%) without cricoid pressure and in 22 of 33 patients (67%) with cricoid pressure (P < 0.05). Cricoid pressure compressed the vocal cords in nine patients (27%) and impeded tracheal tube placement in five (15%). In three patients (9%), pressure had to be released in order to successfully intubate.
CONCLUSION: Cricoid pressure may impede or even prevent fibreoptic laryngoscopic intubation with the WuScope System(TM).

Entities:  

Mesh:

Year:  2002        PMID: 12067876     DOI: 10.1007/BF03017391

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  3 in total

1.  [Video laryngoscopy for modified rapid sequence induction of anaesthesia: Sellick manoever with and without video laryngoscopic control].

Authors:  K Goldmann; G Kalmus; T Steinfeldt; I Friedrich; H Wulf
Journal:  Anaesthesist       Date:  2006-04       Impact factor: 1.041

2.  Effect of Cricoid Pressure on Laryngeal View During Macintosh, McGrath MAC X-Blade and GlideScope Video Laryngoscopies.

Authors:  Zehra İpek Arslan; Mine Solak
Journal:  Turk J Anaesthesiol Reanim       Date:  2017-11-29

Review 3.  Effectiveness and risks of cricoid pressure during rapid sequence induction for endotracheal intubation.

Authors:  Catherine M Algie; Robert K Mahar; Hannah B Tan; Greer Wilson; Patrick D Mahar; Jason Wasiak
Journal:  Cochrane Database Syst Rev       Date:  2015-11-18
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.