Literature DB >> 12064534

Determination of phosphine in biogas and sludge at ppt-levels with gas chromatography-thermionic specific detection.

Joris Roels1, Herman Van Langenhove, Willy Verstraete.   

Abstract

A gas chromatographic (GC) system to measure free phosphine in biogas and matrix bound phosphine in manure and sludge is presented. The system consists of a sample preconcentration trap filled with glass beads, connected with a capillary GC equipped with a thermionic specific detector. With a trap temperature as low as -155 degrees C, a sampling flow of 20 ml/min and a typical total sample volume of 100 ml, free phosphine concentrations in the low ng/m3 range and matrix bound phosphine in the low ng/kg dry matter range, can be accurately and reproducibly determined.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12064534     DOI: 10.1016/s0021-9673(02)00084-5

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  Combustive approach for measuring total volatile phosphorus content in landfill gas.

Authors:  Joris Roels; Frank Vanhaecke; Willy Verstraete
Journal:  Environ Monit Assess       Date:  2005-02       Impact factor: 2.513

2.  An update on toxicology of aluminum phosphide.

Authors:  Ali Akbar Moghadamnia
Journal:  Daru       Date:  2012-09-03       Impact factor: 3.117