Literature DB >> 12062647

Multiple fiber-optic dual-beam UV/Vis system with application to dissolution testing.

Jonas Johansson1, Michael Cauchi, Mats Sundgren.   

Abstract

A system for fiber-optic probing in dissolution testing of solid pharmaceutical formulations has been constructed. The system is based on an imaging spectrometer and a charged coupled device (CCD) detector and includes 12 fiber-optic probes with a novel dual-path design. UV light was produced by a small arc deuterium lamp illuminating an optical fiber bundle. Twelve fiber-optic dipping probes were constructed with a reflection geometry. A 5 mm diameter lens was used to achieve a parallel light beam. The light passed back and forth through the flow-through cuvette defined by a sapphire window and a coated aluminium mirror. The mirror was cut in half and each segment was tilted and set at different distances from the window to obtain two separate paths with different lengths. Two receiver fibers were used for each probe to collect the transmitted light. The 24 receiver fibers from the 12 probes were bunched to a linear bundle and fed to an imaging spectrometer and the corresponding spectra were detected with a 512 x 512 pixel cooled CCD detector. The sampling interval was typically a few seconds for all probes. A software package was developed for data recording and on-line analysis. The program includes tools for multi-component analysis. The system was tested for different tablet formulations. Prednisone 50 mg tablets, normally used for control tests of dissolution baths, were followed for 3 h. Secondly, an extended release low dosage tablet was followed for 7 h resulting in a linear dissolution profile. Finally, a combination tablet containing two active drugs was tested for 60 min profiles. In the latter case, separate dissolution curves for the two active components were obtained. Future work will mainly focus on further development of the multi-component capability of the system.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12062647     DOI: 10.1016/s0731-7085(02)00091-2

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  2 in total

1.  Influence of particle size on the ultraviolet spectrum of particulate-containing solutions: implications for in-situ concentration monitoring using UV/Vis fiber-optic probes.

Authors:  Bernard Van Eerdenbrugh; David E Alonzo; Lynne S Taylor
Journal:  Pharm Res       Date:  2011-03-04       Impact factor: 4.200

2.  Effects of temperature and wavelength choice on in-situ dissolution test of Cimetidine tablets.

Authors:  Xin-Xia Li; Yan Wang; Ping-Ping Xu; Qi-Zhou Zhang; Kun Nie; Xu Hu; Bin Kong; Li Li; Jian Chen
Journal:  J Pharm Anal       Date:  2012-06-19
  2 in total