Literature DB >> 12061358

Reliability of the SNAP (score of neonatal acute physiology) data collection in mechanically ventilated term babies in New South Wales, Australia.

L Sutton1, B Bajuk, G Berry, G P Sayer, B L Eagles, D J Henderson-Smart.   

Abstract

UNLABELLED: The aim of this population-based, case-control, cohort study was to report inter-rater reliability between the New South Wales Neonatal Intensive Care Unit Data Collection (NICUS) audit nurses' collection of SNAP (OS) and a research nurse's SNAP data as the audit SNAP (AS). The study was carried out in Sydney and four large rural/urban health areas in New South Wales (NSW), Australia. The subjects--182 singleton term infants with no major congenital anomalies--were admitted to a tertiary neonatal intensive care unit (NICU) for mechanical ventilation. SNAP data were collected on the 182 case infants, born between 1 January and 31 December 1996, by clinical audit officers in the nine tertiary NICUs in NSW. The research officer conducted an audit of the original SNAP score on all infants. The data were examined using Pearson's correlation coefficient, weighted kappa, a plot of difference in SNAP against mean SNAP and Wilcoxon's signed rank sum test. Pearson's correlation coefficient between the OS and AS data was 0.80. Median (interquartile range) SNAP was 13 (9,19) for the OS and 14 (10,20) for the AS. Weighted kappa was highest for highest heart rate, paO2, temperature (degrees C), oxygenation index, haematocrit, platelet count, lowest serum sodium, lowest blood glucose and seizure. In 17 (9%) infants, OS and AS differed by > or = 10, 14 because of an original data collection error, 1 data entry error, 1 audit error and 1 for both data collection and data entry errors.
CONCLUSION: If SNAP is to be incorporated into any routine NICU data collection, it should be audited regularly on a sample of records. It is important to standardize and adhere to strict definitions for parameters before the collection of SNAP data.

Entities:  

Mesh:

Year:  2002        PMID: 12061358     DOI: 10.1080/080352502317371661

Source DB:  PubMed          Journal:  Acta Paediatr        ISSN: 0803-5253            Impact factor:   2.299


  2 in total

1.  Assessing mortality risk in very low birthweight infants: a comparison of CRIB, CRIB-II, and SNAPPE-II.

Authors:  L Gagliardi; A Cavazza; A Brunelli; M Battaglioli; D Merazzi; F Tandoi; D Cella; G F Perotti; M Pelti; I Stucchi; F Frisone; A Avanzini; R Bellù
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2004-09       Impact factor: 5.747

2.  Effect of High-Dose Cysteine Supplementation on Erythrocyte Glutathione: A Double-Blinded, Randomized Placebo-Controlled Pilot Study in Critically Ill Neonates.

Authors:  Kara L Calkins; Lauren A Sanchez; Chi-Hong Tseng; Kym F Faull; Alexander J Yoon; Christopher M Ryan; Thuc Le; Stephen B Shew
Journal:  JPEN J Parenter Enteral Nutr       Date:  2014-08-19       Impact factor: 4.016

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.