Reference values for a heterogeneous ferritin assay and traceability to the 3rd International Recombinant Standard for Ferritin (NIBSC code 94/572).

Ahmad Hamwi1, Georg Endler, Karl Rubi, Oswald Wagner, Arno Thomas Endler.   

Abstract

Reference values for Ferritin Flex on the Dimension RxL analyzer calibrated against the 3rd International Standard for Ferritin (recombinant) and N-Latex Ferritin on the BNA II nephelometer calibrated against the 2nd International Standard for Ferritin (spleen) both from Dade Behring (Marburg, Germany) were established (77 men and 182 women). Exclusion criteria were iron deficiency or iron deficiency anemia, inflammation, liver disease, malignancy, and other hematological or chronic disorders. The reference values (5.0th-95th percentiles) were as follow: for N-Latex Ferritin - men, 12-399 microg/l; women <50 years, 11-102 microg/l and women > or =50 years, 17-219 microg/l; for Ferritin Flex - men, 14-415 microg/l; women <50 years, 11-111 microg/l and women > or =50 years, 22-224 microg/l. Both assays correlated very closely with each other (r=0.993). The linearity was acceptable down to 2 microg/l for the Ferritin Flex method, but only down to 15 microg/l for the N-Latex Ferritin assay. The mean recovery of the 3rd International Standard by N-Latex Ferritin and Ferritin Flex was comparable (approximately 80%). We conclude that the new Ferritin Flex assay, which is based on the new 3rd International Standard, should be used for ferritin measurement in the routine medical laboratories in the future.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12059077     DOI: 10.1515/CCLM.2002.059

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  2 in total

1.  A Comparative Study for Measuring Serum Ferritin Levels with Three Different Laboratory Methods: Enzyme-Linked Immunosorbent Assay versus Cobas e411 and Cobas Integra 400 Methods.

Authors:  Lotfi S Bin Dahman; Khalid M Sumaily; Essa M Sabi; Mohammed A Hassan; Abeer M Bin Thalab; Asrar S Sayad; Saleh M Bin Kolaib; Fatima M Alhadhrmi
Journal:  Diagnostics (Basel)       Date:  2022-01-27

Review 2.  Performance and comparability of laboratory methods for measuring ferritin concentrations in human serum or plasma: A systematic review and meta-analysis.

Authors:  Maria N Garcia-Casal; Juan P Peña-Rosas; Eloisa Urrechaga; Jesus F Escanero; Junsheng Huo; Ricardo X Martinez; Lucero Lopez-Perez
Journal:  PLoS One       Date:  2018-05-03       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.