Literature DB >> 12058290

[Initial findings with pulsar perimetry in patients with ocular hypertension].

A Vidal-Fernández1, J García Feijoó, M González-Hernández, M González De La Rosa, J García Sánchez.   

Abstract

PURPOSE: To evaluate our first results with Pulsar perimetry in patients with ocular hypertension and compare them with normal individuals.
METHODS: We studied 34 eyes of patients with ocular hypertension and normal G1 Octopus perimetry (mean age: 57.29 S.D. 10.55) and 41 eyes of normal individuals (mean age: 48.34 S.D. 13.71). A complete ophthalmologic examination, including Dr. González de la Rosa's Pulsar perimetry with TOP strategy, was performed for all patients. EXCLUSION CRITERIA: visual acuity <0.8, refractive defect 3 spheric dp or 1.5 astigmatic dp, pupil size <3 mm, ocular surgery or pathologies, non-controlled diabetes or neurological diseases. They all had previous perimetric experience. Results were analyzed with student t - test.
RESULTS: For normal individuals, mean sensitivity (MS) for Pulsar perimetry was 21,25 src (spatial resolution and contrast units) with an S.D. of 2,70. Mean defect (MD) was 0,93 src S.D. 1,80 and loss variance (LV) was 6,11 src S.D. 4,30. For patients with ocular hypertension: MS was 18,65 src S.D. 2,79; MD was 2,73 src S.D. 2,30 and LV was 8,46 src S.D. 5,01. LV differences between the two groups were statistically significant (p<0.05) with 95% confidence limits of (-4.49; -0.20), and MS and MD differences, highly significant (p<0.01), with 99% confidence limits of (+0.92; +4.28;) and (-3.05; -0.54) respectively.
CONCLUSIONS: Pulsar perimetry may have greater sensibility for the detection of early defects in patients with ocular hypertension than conventional perimetry.

Entities:  

Mesh:

Year:  2002        PMID: 12058290

Source DB:  PubMed          Journal:  Arch Soc Esp Oftalmol        ISSN: 0365-6691


  6 in total

1.  [Importance of flicker contrast tests in functional glaucoma diagnostics].

Authors:  K Göbel; C M Poloschek; C Erb; M Bach
Journal:  Ophthalmologe       Date:  2012-04       Impact factor: 1.059

Review 2.  [Pulsar perimetry. A review and new results].

Authors:  M Gonzalez de la Rosa; M Gonzalez-Hernandez
Journal:  Ophthalmologe       Date:  2013-02       Impact factor: 1.059

3.  [Sensitivity and specificity of flicker perimetry with Pulsar. Comparison with achromatic (white-on-white) perimetry in glaucoma patients].

Authors:  K Göbel; C Erb
Journal:  Ophthalmologe       Date:  2013-02       Impact factor: 1.059

4.  Influence of ACPA-positive rheumatoid arthritis on visual field testing in patients with arterial hypertension: A comparative cross-sectional study.

Authors:  Jascha Wendelstein; Barbara Fuchs; Sarah Schlittgen; Robert Zielke; Jeanette Brünner; Matthias Bolz; Rielke Alten; Carl Erb
Journal:  Ophthalmic Physiol Opt       Date:  2021-06-02       Impact factor: 3.117

5.  Comparison between the Correlations of Retinal Nerve Fiber Layer Thickness Measured by Spectral Domain Optical Coherence Tomography and Visual Field Defects in Standard Automated White-on-White Perimetry versus Pulsar Perimetry.

Authors:  Maged Alnawaiseh; Lisann Hömberg; Nicole Eter; Verena Prokosch
Journal:  J Ophthalmol       Date:  2017-10-08       Impact factor: 1.909

6.  The Diagnostic Value of Pulsar Perimetry, Optical Coherence Tomography, and Optical Coherence Tomography Angiography in Pre-Perimetric and Perimetric Glaucoma.

Authors:  Hung-Chih Chen; Michael Chia-Yen Chou; Ming-Tsung Lee; Chia-Yi Lee; Che-Ning Yang; Chin-Hsin Liu; Shih-Chun Chao
Journal:  J Clin Med       Date:  2021-12-13       Impact factor: 4.241

  6 in total