Literature DB >> 12053326

The use of Amplatzer devices to occlude vascular fistulae.

J V de Giovanni1.   

Abstract

The Amplatzer occluders are Nitinol-based devices that are preshaped for specific indications, primarily to close atrial septal defects, patent foramen ovale/fenestrations, or to occlude patent arterial ducts or one designed specifically for closure of ventricular septal defects. The flexible quality of the Nitinol together with the different designs of Amplatzer occluders make it possible for these plug devices to be used for conditions other than what they are designed for. This is particularly the case for fistulae where no specific devices are available and hence improvisation may be required. The established use of the Amplatzer occluder devices primarily for atrial septal defects and for patent arterial ducts provide the confidence to use them for alternative conditions where few or no alternatives are available or if surgery is the only option. This article describes the use of Amplatzer occluder devices for two unusual conditions, namely to occlude a pulmonary arteriovenous malformation and to close an aorto-left ventricular tunnel.

Entities:  

Mesh:

Year:  2001        PMID: 12053326     DOI: 10.1111/j.1540-8183.2001.tb00710.x

Source DB:  PubMed          Journal:  J Interv Cardiol        ISSN: 0896-4327            Impact factor:   2.279


  5 in total

1.  Transcatheter occlusion of a large pulmonary arteriovenous malformation using the Amplatzer vascular plug.

Authors:  H Farra; D T Balzer
Journal:  Pediatr Cardiol       Date:  2005 Sep-Oct       Impact factor: 1.655

2.  Interventional occlusion of a thrombosed aortic conduit.

Authors:  Mark D Townsend; William B Moskowitz
Journal:  Pediatr Cardiol       Date:  2006-07-11       Impact factor: 1.655

3.  Occlusion of the common and internal iliac arteries for aortoiliac aneurysm repair: experience with the Amplatzer vascular plug.

Authors:  S Marlene Grenon; Joel Gagnon; York Hsiang; Ravi Sidhu; David Taylor; Jason Clement; Jerry Chen
Journal:  Can J Surg       Date:  2009-12       Impact factor: 2.089

4.  Closing the gap between coil and balloon in the neurointerventional armamentarium? Initial clinical experience with a nitinol vascular occlusion plug.

Authors:  Jan Gralla; Gerhard Schroth; Ralph Kickuth; Marwan El-Koussy; Dai-Do Do; Caspar Brekenfeld
Journal:  Neuroradiology       Date:  2008-05-28       Impact factor: 2.804

5.  Massive retroperitoneal hemorrhage from a giant renal angiomyolipoma treated by selective arterial embolization with an Amplatzer Vascular Plug II.

Authors:  Ulf Km Teichgräber; Maximilian De Bucourt
Journal:  Acta Radiol Short Rep       Date:  2012-02-15
  5 in total