Literature DB >> 12051900

Automatic alignment of transmission electron microscope tilt series without fiducial markers.

S Brandt1, J Heikkonen, P Engelhardt.   

Abstract

Accurate image alignment is needed for computing three-dimensional reconstructions from transmission electron microscope tilt series. So far, the best results have been obtained by using colloidal gold beads as fiducial markers. If their use has not been possible for some reason, the only option has been the automatic cross-correlation-based registration methods. However, the latter methods are inaccurate and, as we will show, inappropriate for the whole problem. Conversely, we propose a novel method that uses the actual 3D motion model but works without any fiducial markers in the images. The method is based on matching and tracking some interest points of the intensity surface by first solving the underlying geometrical constraint of consecutive images in the tilt series. The results show that our method is near the gold marker alignment in the level of accuracy and hence opens the way for new opportunities in the analysis of electron tomography reconstructions, especially when markers cannot be used. (c)2002 Elsevier Science (USA).

Mesh:

Year:  2001        PMID: 12051900     DOI: 10.1006/jsbi.2001.4443

Source DB:  PubMed          Journal:  J Struct Biol        ISSN: 1047-8477            Impact factor:   2.867


  11 in total

Review 1.  3D electron microscopy of biological nanomachines: principles and applications.

Authors:  C O S Sorzano; S Jonic; M Cottevieille; E Larquet; N Boisset; S Marco
Journal:  Eur Biophys J       Date:  2007-07-05       Impact factor: 1.733

Review 2.  Reconstructing virus structures from nanometer to near-atomic resolutions with cryo-electron microscopy and tomography.

Authors:  Juan Chang; Xiangan Liu; Ryan H Rochat; Matthew L Baker; Wah Chiu
Journal:  Adv Exp Med Biol       Date:  2012       Impact factor: 2.622

3.  Automated tilt series alignment and tomographic reconstruction in IMOD.

Authors:  David N Mastronarde; Susannah R Held
Journal:  J Struct Biol       Date:  2016-07-19       Impact factor: 2.867

Review 4.  New insights into HTLV-1 particle structure, assembly, and Gag-Gag interactions in living cells.

Authors:  Keir H Fogarty; Wei Zhang; Iwen F Grigsby; Jolene L Johnson; Yan Chen; Joachim D Mueller; Louis M Mansky
Journal:  Viruses       Date:  2011-06-14       Impact factor: 5.048

5.  Marker-free image registration of electron tomography tilt-series.

Authors:  Carlos Oscar Sanchez Sorzano; Cédric Messaoudi; Matthias Eibauer; J R Bilbao-Castro; R Hegerl; S Nickell; S Marco; J M Carazo
Journal:  BMC Bioinformatics       Date:  2009-04-27       Impact factor: 3.169

6.  Geometric correction method for 3D in-line X-ray phase contrast image reconstruction.

Authors:  Geming Wu; Mingshu Wu; Linan Dong; Shuqian Luo
Journal:  Biomed Eng Online       Date:  2014-07-29       Impact factor: 2.819

7.  The advent of structural biology in situ by single particle cryo-electron tomography.

Authors:  Jesús G Galaz-Montoya; Steven J Ludtke
Journal:  Biophys Rep       Date:  2017-05-29

8.  Fast Projection Matching for X-ray Tomography.

Authors:  Chun-Chieh Wang; Cheng-Cheng Chiang; Biqing Liang; Gung-Chian Yin; Yi-Tse Weng; Liang-Chi Wang
Journal:  Sci Rep       Date:  2017-06-16       Impact factor: 4.379

9.  Rapid alignment of nanotomography data using joint iterative reconstruction and reprojection.

Authors:  Doğa Gürsoy; Young P Hong; Kuan He; Karl Hujsak; Seunghwan Yoo; Si Chen; Yue Li; Mingyuan Ge; Lisa M Miller; Yong S Chu; Vincent De Andrade; Kai He; Oliver Cossairt; Aggelos K Katsaggelos; Chris Jacobsen
Journal:  Sci Rep       Date:  2017-09-18       Impact factor: 4.379

10.  A fast fiducial marker tracking model for fully automatic alignment in electron tomography.

Authors:  Renmin Han; Fa Zhang; Xin Gao
Journal:  Bioinformatics       Date:  2018-03-01       Impact factor: 6.937

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.