Ultrasound-based vessel wall tracking: an auto-correlation technique with RF center frequency estimation.

Stein Inge Rabben1, Steinar Baerum, Vidar Sørhus, Hans Torp.   

Abstract

Vessel diameter is related to the distending blood pressure, and is used in estimations of vessel stiffness parameters. The vessel walls can be tracked by integrating wall velocities estimated by ultrasound (US) Doppler techniques. The purpose of this work was to evaluate the performance of the modified autocorrelation estimator when applied on vessel wall motion. As opposed to the conventional autocorrelation method that only estimates the mean Doppler frequency, the modified autocorrelation method estimates both the mean Doppler frequency and the radiofrequency (RF) center frequency. To make a systematic evaluation of the estimator, we performed computer simulations of vessel wall motion, where pulse bandwidth, signal-to-noise ratio (SNR), signal-to-reverberation ratio, packet size and sample volume were varied. As reference, we also analyzed the conventional autocorrelation method and the cross-correlation method with parabolic interpolation. Under the simulation conditions considered here, the modified autocorrelation method had the lowest bias and variance of the estimators. When integrating velocity estimates over several cardiac cycles, the resulting tissue displacement curves might drift. This drift is directly related to the magnitude of the estimator bias and variance. Hence, the modified autocorrelation method should be the preferred choice of method.

Mesh:

Year:  2002        PMID: 12049964     DOI: 10.1016/s0301-5629(02)00487-8

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  7 in total

1.  Adaptive clutter rejection filtering in ultrasonic strain-flow imaging.

Authors:  Christian Kargel; Gernot Höbenreich; Birgit Trummer; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-07       Impact factor: 2.725

Review 2.  Recent developments in vascular ultrasound technology.

Authors:  P R Hoskins; D A Kenwright
Journal:  Ultrasound       Date:  2015-03-26

3.  Therapeutic Ultrasound Effects on Human Induced Pluripotent Stem Cell Cardiomyocytes Measured Optically and with Spectral Ultrasound.

Authors:  Andrew W Chen; George Saab; Aleksandar Jeremic; Vesna Zderic
Journal:  Ultrasound Med Biol       Date:  2022-03-15       Impact factor: 3.694

4.  Numerical assessment of time-domain methods for the estimation of local arterial pulse wave speed.

Authors:  Jordi Alastruey
Journal:  J Biomech       Date:  2011-01-05       Impact factor: 2.712

5.  Feasibility Study of Ex Ovo Chick Chorioallantoic Artery Model for Investigating Pulsatile Variation of Arterial Geometry.

Authors:  Kweon-Ho Nam; Juho Kim; Gicheol Ra; Chong Hyun Lee; Dong-Guk Paeng
Journal:  PLoS One       Date:  2015-12-30       Impact factor: 3.240

6.  A new high-resolution spectral approach to noninvasively evaluate wall deformations in arteries.

Authors:  Ivonne Bazan; Carlos Negreira; Antonio Ramos; Javier Brum; Alfredo Ramirez
Journal:  Comput Math Methods Med       Date:  2014-02-13       Impact factor: 2.238

7.  Quest for the Vulnerable Atheroma: Carotid Stenosis and Diametric Strain--A Feasibility Study.

Authors:  Canxing Xu; Chun Yuan; Edward Stutzman; Gador Canton; Keith A Comess; Kirk W Beach
Journal:  Ultrasound Med Biol       Date:  2015-12-23       Impact factor: 2.998

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.