Myocardial blood flow measurements in rats with simple pulsing contrast echocardiography.

Akira Oshita1, Koji Ohmori, Yang Yu, Isao Kondo, Hiroto Takeuchi, Yuichiro Takagi, Yoshihiro Wada, Kazushi Yukiiri, Katsufumi Mizushige, Masakazu Kohno.   

Abstract

Relationship between contrast intensity and ultrasound (US) pulsing interval has been utilized to quantify myocardial blood flow (MBF) during myocardial contrast echocardiography (MCE). We tested if an MCE method employing a simple pulsing sequence during intravenous contrast infusion has the ability to quantify MBF in rats. We performed MCE in 17 rats using a 5- to 12-MHz broadband transducer during microbubble infusion via the femoral vein. Acoustic density (AD) from the anterior wall of the left ventricle imaged in the short axis plane was plotted against the frame number after shortening the pulsing interval (PI) from 1:20 to 1:1 end-systolic ECG gating. The relation between AD and frame number was fitted to a decay function. The rate of the AD decay was decreased during dipyridamole infusion, but was increased by causing coronary stenosis. The AD during long PI imaging remained unchanged during the interventions. Estimated MBF by MCE after correction by heart rate exhibited a close correlation (r = 0.83) with the present "gold standard" of colored microsphere-derived MBF. Thus, the decay rate of the contrast intensity obtained with the high-frequency transducer after abrupt shortening of PI during intravenous microbubble infusion may provide for noninvasive measurement of MBF in rats.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12049959     DOI: 10.1016/s0301-5629(02)00481-7

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  4 in total

1.  Participation of mast cells in angiogenesis in the border zone of myocardial infarction in rats.

Authors:  Takayoshi Yamaki; Masumi Iwai-Takano; Hiroyuki Yaoita; Kazuei Ogawa; Hiroko Tajima; Yasuchika Takeishi; Yukio Maruyama
Journal:  J Med Ultrason (2001)       Date:  2009-08-15       Impact factor: 1.314

2.  Cardiac perfusion imaging using hyperpolarized (13)C urea using flow sensitizing gradients.

Authors:  Angus Z Lau; Jack J Miller; Matthew D Robson; Damian J Tyler
Journal:  Magn Reson Med       Date:  2015-05-20       Impact factor: 4.668

3.  Effect of streptozotocin-induced diabetes on myocardial blood flow reserve assessed by myocardial contrast echocardiography in rats.

Authors:  Bernard Cosyns; Steven Droogmans; Sophie Hernot; Céline Degaillier; Christian Garbar; Caroline Weytjens; Bram Roosens; Danny Schoors; Tony Lahoutte; Philippe R Franken; Guy Van Camp
Journal:  Cardiovasc Diabetol       Date:  2008-09-02       Impact factor: 9.951

4.  In vivo characterization of rodent cyclic myocardial perfusion variation at rest and during adenosine-induced stress using cine-ASL cardiovascular magnetic resonance.

Authors:  Thomas Troalen; Thibaut Capron; Monique Bernard; Frank Kober
Journal:  J Cardiovasc Magn Reson       Date:  2014-02-18       Impact factor: 5.364

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.