Literature DB >> 12047540

Determination of gestational age after the 24th week of gestation from fetal kidney length measurements.

J C Konje1, K R Abrams, S C Bell, D J Taylor.   

Abstract

OBJECTIVE: To evaluate the application of kidney length measurement to the determination of gestational age between the 24th and 38th weeks and to compare its accuracy with that of other fetal biometric indices. STUDY
DESIGN: Seventy-three women with singleton uncomplicated pregnancies underwent standard ultrasound fetal biometry and kidney length measurement every 2 weeks between 24 and 38 weeks' gestation. These measurements were used to date the pregnancies relative to crown-rump length dating between 8 and 10 weeks' gestation. Linear regression models for estimation of gestational age were derived from the biometric indices and kidney length. In addition, stepwise regression models were constructed to determine the best model for determining gestational age between 24 and 38 weeks. Comparisons were then made between the accuracy of these models in the determination of gestational age.
RESULTS: The best model for estimating gestational age in late pregnancy included the variables kidney length, biparietal diameter, head circumference, femur length and abdominal circumference. This model accurately predicted gestational age with a standard error of +/- 8.48 days. A model including kidney length, biparietal diameter, head circumference and femur length accurately predicted gestational age with a standard error of +/- 8.57 days. These models were slightly more accurate than models derived from the biometric indices of biparietal diameter, head circumference and femur length (+/- 9.87 days), biparietal diameter, head circumference, femur length and abdominal circumference (+/- 9.45 days) and biparietal diameter and femur length (+/- 9.9 days). Kidney length and femur length were the most accurate single parameters for predicting gestational age using simple linear regression models (+/- 10.29 and 10.96 days, respectively); the abdominal circumference was the least accurate (+/- 14.54 days).
CONCLUSION: Kidney length is a more accurate method of determining gestational age than the fetal biometric indices of biparietal diameter, head circumference, femur length and abdominal circumference between 24 and 38 weeks' gestation. When combined with biparietal diameter, head circumference and femur length, the precision of dating is improved by 2 days. This measurement is easy to make and could therefore be easily incorporated into the model for dating pregnancies after 24 weeks of gestation, in particular when measurements of the biparietal diameter and head circumference are difficult.

Entities:  

Mesh:

Year:  2002        PMID: 12047540     DOI: 10.1046/j.1469-0705.2002.00704.x

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  7 in total

1.  Size and location of the kidneys during the fetal period.

Authors:  Osman Sulak; Gülnur Ozgüner; Mehmet Ali Malas
Journal:  Surg Radiol Anat       Date:  2010-11-26       Impact factor: 1.246

2.  Anterior-posterior thigh diameter measured by two-dimensional sonography: indicator of fetal age at 18 to 28 weeks gestation ?

Authors:  Saad R I Al-Kubaisi
Journal:  Sultan Qaboos Univ Med J       Date:  2006-12

Review 3.  Applications of high-resolution magic angle spinning MRS in biomedical studies II-Human diseases.

Authors:  Christopher Dietz; Felix Ehret; Francesco Palmas; Lindsey A Vandergrift; Yanni Jiang; Vanessa Schmitt; Vera Dufner; Piet Habbel; Johannes Nowak; Leo L Cheng
Journal:  NMR Biomed       Date:  2017-09-15       Impact factor: 4.044

4.  Sonographic estimation of gestational age from 20 to 40 weeks by fetal kidney lengths' measurements among pregnant women in Portharcourt, Nigeria.

Authors:  Everistus Obinna Abonyi; Charles Ugwoke Eze; Kennedy Kenechukwu Agwuna; Warric Sobechukwu Onwuzu
Journal:  BMC Med Imaging       Date:  2019-08-22       Impact factor: 1.930

Review 5.  Second and third trimester estimation of gestational age using ultrasound or maternal symphysis-fundal height measurements: A systematic review.

Authors:  Alice Self; Lama Daher; Michael Schlussel; Nia Roberts; Christos Ioannou; Aris T Papageorghiou
Journal:  BJOG       Date:  2022-03-10       Impact factor: 7.331

6.  Quantitative metabolic profiles of 2nd and 3rd trimester human amniotic fluid using (1)H HR-MAS spectroscopy.

Authors:  Brad R Cohn; Bonnie N Joe; Shoujun Zhao; John Kornak; Vickie Y Zhang; Rahwa Iman; John Kurhanewicz; Kiarash Vahidi; Jingwei Yu; Aaron B Caughey; Mark G Swanson
Journal:  MAGMA       Date:  2009-09-25       Impact factor: 2.310

7.  Fetal kidney length as a useful adjunct parameter for better determination of gestational age.

Authors:  Mete G Ugur; Aynur Mustafa; Huseyin C Ozcan; Neslihan B Tepe; Huseyin Kurt; Emre Akcil; Reyhan Gunduz
Journal:  Saudi Med J       Date:  2016-05       Impact factor: 1.484

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.