The daily force pattern of spinal orthoses in subjects with adolescent idiopathic scoliosis.

E Lou1, J V Raso, D L Hill, N G Durdle, J K Mahood, M J Moreau.   

Abstract

The efficacy of orthotic treatment for children with abnormal spinal curvature has been hampered by the lack of comprehensive information about wear characteristics. A battery-powered microcomputer system was developed to monitor loads exerted by orthoses used to treat children with spinal deformities during daily living. The system not only records how well the orthosis has been used, but also helps to ensure that the orthosis is being worn as prescribed. Data acquisition is controlled by a microcontroller and can be programmed to have sample intervals ranging from 1 second to 1 hour. Low power control circuitry is designed so that the system can be operated by a battery. In a preliminary study, 16 subjects (3M, 13F) used this system from 1 to 16 days (9.3 +/- 5.0) with the prescribed hours between 16 to 23 hours (22.3 +/- 1.3). This study demonstrated the feasibility of the approach, and that this device may increase the understanding of orthotic mechanics, and may help patients to wear their orthoses in a better way.

Entities:  

Mesh:

Year:  2002        PMID: 12043927     DOI: 10.1080/03093640208726622

Source DB:  PubMed          Journal:  Prosthet Orthot Int        ISSN: 0309-3646            Impact factor:   1.895


  6 in total

1.  A wireless sensor network system to determine biomechanics of spinal braces during daily living.

Authors:  Edmond Lou; Doug L Hill; James V Raso
Journal:  Med Biol Eng Comput       Date:  2010-01-22       Impact factor: 2.602

2.  Electronic monitoring of scoliosis brace wear compliance.

Authors:  Tariq Rahman; Battugs Borkhuu; Aaron G Littleton; Whitney Sample; Ed Moran; Stephen Campbell; Kenneth Rogers; J Richard Bowen
Journal:  J Child Orthop       Date:  2010-06-03       Impact factor: 1.548

3.  Smart orthosis for the treatment of adolescent idiopathic scoliosis.

Authors:  E Lou; D L Hill; J V Raso; M J Moreau; J K Mahood
Journal:  Med Biol Eng Comput       Date:  2005-11       Impact factor: 2.602

4.  [The preliminary clinical application of a smart orthosis personalized management system for the treatment of patients with adolescent idiopathic scoliosis].

Authors:  Ce Zhu; Qiang Wu; Bing Xiao; Juehan Wang; Chao Luo; Quan Yu; Limin Liu; Yueming Song
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-07-15

5.  Electronic monitoring of orthopedic brace compliance.

Authors:  Tariq Rahman; Whitney Sample; Petya Yorgova; Geraldine Neiss; Kenneth Rogers; Suken Shah; Peter Gabos; Dan Kritzer; J Richard Bowen
Journal:  J Child Orthop       Date:  2015-08-28       Impact factor: 1.548

6.  A compliance real-time monitoring system for the management of the brace usage in adolescent idiopathic scoliosis patients: a pilot study.

Authors:  Ce Zhu; Qiang Wu; Bing Xiao; Juehan Wang; Chao Luo; Quan Yu; Limin Liu; Yueming Song
Journal:  BMC Musculoskelet Disord       Date:  2021-02-05       Impact factor: 2.362

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.