Literature DB >> 12043876

Root-end fracture during retropreparation: a comparison between zirconium nitride-coated and stainless steel microsurgical ultrasonic instruments.

Stephen William Navarre1, H Robert Steiman.   

Abstract

The purpose of this study was to evaluate a stainless steel (CT-5) and zirconium nitride coated (KiS) microsurgical ultrasonic instrument with regard to possible root-end fracture production during retropreparation. Forty extracted human central incisors were prepared in a crown-down fashion. Canals were obturated with gutta-percha by lateral condensation. Root-ends were resected. Teeth were placed in methylene blue for 48 h and evaluated by three independent evaluators under microscope. Teeth with existing fractures were eliminated from the study. The remaining teeth were randomly divided into two equal groups. Group A was prepared with the CT-5 tip and Group B with the KiS tip. Preparation time was recorded for all roots. The teeth were again immersed in methylene blue for 48 h and reevaluated. No root-end fractures were produced by either the KiS or CT-5 microsurgical ultrasonic instruments.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12043876     DOI: 10.1097/00004770-200204000-00018

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  8 in total

1.  Ultrasonics in endodontic surgery: a review of the literature.

Authors:  Gianfranco De Paolis; Valentina Vincenti; Matteo Prencipe; Valerio Milana; Gianluca Plotino
Journal:  Ann Stomatol (Roma)       Date:  2010-12-08

2.  Effects of ultrasonic refinement on endodontic access cavity walls: A microcomputed tomography analysis.

Authors:  Carla Zogheib; Reina Roumi; Gaël Bourbouze; Alfred Naaman; Issam Khalil; Gianluca Plotino
Journal:  J Conserv Dent       Date:  2021-07-05

3.  Effect of ultrasonic tip and root-end filling material on bond strength.

Authors:  Rodrigo Ricci Vivan; Juliane Maria Guerreiro-Tanomaru; Ricardo Affonso Bernardes; José Mauricio Santos Nunes Reis; Marco Antonio Hungaro Duarte; Mário Tanomaru-Filho
Journal:  Clin Oral Investig       Date:  2016-01-09       Impact factor: 3.573

4.  CO(2), Er: YAG and Nd:YAG lasers in endodontic surgery.

Authors:  Daniel Humberto Pozza; Patrícia Wehmeyer Fregapani; Cristina Braga Xavier; João Batista Blessmann Weber; Marília Gerhardt de Oliveira
Journal:  J Appl Oral Sci       Date:  2009 Nov-Dec       Impact factor: 2.698

5.  Effects of ultrasonic root-end cavity preparation with different surgical-tips and at different power-settings on glucose-leakage of root-end filling material.

Authors:  Betul Gunes; Hale Ali Aydinbelge
Journal:  J Conserv Dent       Date:  2014-09

6.  Evaluation of apical preparations performed with ultrasonic diamond and stainless steel tips at different intensities using a scanning electron microscope in endodontic surgery.

Authors:  Ramón Rodríguez-Martos; Daniel Torres-Lagares; Lizett Castellanos-Cosano; María-Angeles Serrera-Figallo; Juan-José Segura-Egea; Jose-Luis Gutierrez-Perez
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-11-01

7.  Evaluation of two different root-end cavity preparation techniques: A scanning electron microscope study.

Authors:  Seda Aydemir; Hale Cimilli; Afife Binnaz Hazar Yoruç; Nevin Kartal
Journal:  Eur J Dent       Date:  2013-04

8.  In Vitro Qualitative Evaluation of Root-End Preparation Performed by Piezoelectric Instruments.

Authors:  Calogero Bugea; Federico Berton; Antonio Rapani; Roberto Di Lenarda; Giuseppe Perinetti; Eugenio Pedullà; Antonio Scarano; Claudio Stacchi
Journal:  Bioengineering (Basel)       Date:  2022-03-02
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.