Unconstrained and non-invasive measurement of heart-beat and respiration periods using a phonocardiographic sensor.

S Tanaka1, Y Matsumoto, K Wakimoto.   

Abstract

With the rapid growth in the number of elderly people in the population, interest in health monitoring is increasing. Therefore the development of an unconstrained and non-invasive vital signs measurement system could be important for monitoring health status at home or in hospitals or nursing facilities. A simple system is proposed for measuring heart-beat and respiration periods for home healthcare. This was achieved with a phonocardiographic (PCG) sensor set on a water-mat or air-mat. The PCG sensor was an acceleration sensor that extracted the vibration of the mat caused by heart-beat and respiration. By calculating an autocorrelation function of the fully rectified sensor output or by local pattern matching between the rectified output and a reference signal (pre-memorised for each subject), the system measured the average and instantaneous periods of both heart-beat and respiration. Results showed that these periods were measured to a similar level of accuracy as for the electrocardiogram and thermistor respiration pickup. The comparative accuracies were within the following ranges: average heartbeat 0.19% to 0.67%, instantaneous heartbeat 0.53% to 1.15%, average respiration 0.51% to 2.17%, and instantaneous respiration 2.51% to 5.20%.

Entities:  

Mesh:

Year:  2002        PMID: 12043808     DOI: 10.1007/bf02348132

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  3 in total

1.  The normal heart sounds in the Japanese--the normal phonocardiogram. I.

Authors:  H UEDA; Z UOZUMI; T SAKAMOTO
Journal:  Jpn Heart J       Date:  1961-10

2.  Cardiopulmonary monitoring by textile electrodes without subject-awareness of being monitored.

Authors:  M Ishijima
Journal:  Med Biol Eng Comput       Date:  1997-11       Impact factor: 2.602

3.  Observation of electrocardiograms through tap water.

Authors:  M Ishijima; T Togawa
Journal:  Clin Phys Physiol Meas       Date:  1989-05
  3 in total
  5 in total

1.  Unconstrained cardiorespiratory and body movement monitoring system for home care.

Authors:  K Niizeki; I Nishidate; K Uchida; M Kuwahara
Journal:  Med Biol Eng Comput       Date:  2005-11       Impact factor: 2.602

2.  A study on a non-contacting respiration signal monitoring system using Doppler ultrasound.

Authors:  Se Dong Min; Dae Joong Yoon; Sung Won Yoon; Yong Hyeon Yun; Myoungho Lee
Journal:  Med Biol Eng Comput       Date:  2007-09-06       Impact factor: 2.602

3.  Unconstrained pulse pressure monitoring for health management using hetero-core fiber optic sensor.

Authors:  Michiko Nishiyama; Masako Sonobe; Kazuhiro Watanabe
Journal:  Biomed Opt Express       Date:  2016-08-26       Impact factor: 3.732

4.  Heart Rate Variability Monitoring during Sleep Based on Capacitively Coupled Textile Electrodes on a Bed.

Authors:  Hong Ji Lee; Su Hwan Hwang; Hee Nam Yoon; Won Kyu Lee; Kwang Suk Park
Journal:  Sensors (Basel)       Date:  2015-05-14       Impact factor: 3.576

5.  Measurement of electrocardiograms in a bath through tap water utilizing capacitive coupling electrodes placed outside the bathtub wall.

Authors:  Kosuke Motoi; Yasuhiro Yamakoshi; Takehiro Yamakoshi; Hiroaki Sakai; Naoto Tanaka; Ken-Ichi Yamakoshi
Journal:  Biomed Eng Online       Date:  2017-01-11       Impact factor: 2.819

  5 in total