Literature DB >> 12042723

Clinical failures of endovascular abdominal aortic aneurysm repair: incidence, causes, and management.

Jeffery B Dattilo1, David C Brewster, Chien-Min Fan, Stuart C Geller, Richard P Cambria, Glenn M Lamuraglia, Alan J Greenfield, Stephen R Lauterbach, William M Abbott.   

Abstract

OBJECTIVE: Despite well-documented good early results and benefits of endoluminal stent graft repair of abdominal aortic aneurysm (J Vasc Surg 2002;35:1137-44.)(AAA), the long-term outcome of this method of treatment remains uncertain. In particular, concern exists that late effectiveness and durability are inferior to that of open repair. To determine the incidence and causes of clinical failures of endovascular AAA repair, a 7-year experience with 362 primary AAA endografts was reviewed.
METHODS: Clinical failures were defined as deaths within 30 days of the procedure, conversions (early and late) to open AAA repair, AAA rupture after endoluminal treatment, or AAA sac growth of more than 5 mm in maximal diameter despite endograft repair. Endoleak status per se was not considered unless it resulted in an adverse event. If clinical problems arose but could be corrected with catheter-based therapies or limited surgical procedures, thereby maintaining the integrity of successful stent graft treatment of the AAA, such cases were considered as primary assisted success and not classified as clinical failures.
RESULTS: The average follow-up period was 1.5 years. Six deaths (1.6%) occurred after the procedure, all in elderly patients or patients at high risk. Five patients (1.4%) needed early conversion (immediate, 2 days) to open repair for access problems or technical difficulties with deployment, resulting in an implantation success rate of 98.6%. Eight patients (2.2%) underwent late conversion for a variety of problems, including AAA expansion (n = 4), endograft thrombosis (n = 1), secondary graft infection (n = 2), and rupture at 3 years (n = 1). Rupture occurred in an additional two patients for a total incidence rate of 0.8%. AAA sac growth of greater than 5 mm was observed in 20 patients (5.6%), four of whom have undergone successful catheter-based treatments to date. Overall, 39 patients (10.7%) needed catheter-based (n = 45) or limited surgical (n = 4) reinterventions for a variety of late problems that were successful in 92%.
CONCLUSION: In our 7-year experience, one or more clinical failures of endovascular AAA repair were observed in 31 patients (8.3%). Reinterventions were necessitated in a total of 10.7% of patients but were usually successful in maintaining AAA exclusion and limiting AAA growth. These results emphasize that endovascular repair provides good results and many benefits for most properly selected patients but is not as durable as standard open repair.

Entities:  

Mesh:

Year:  2002        PMID: 12042723     DOI: 10.1067/mva.2002.124627

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  8 in total

1.  Intra-arterial Device Infections.

Authors:  Vera S. Antonios; Larry M. Baddour
Journal:  Curr Infect Dis Rep       Date:  2004-08       Impact factor: 3.725

2.  Causes of late mortality after endovascular and open surgical repair of infrarenal abdominal aortic aneurysms.

Authors:  Philip P Goodney; Dale Tavris; F Lee Lucas; Thomas Gross; Elliott S Fisher; Samuel R G Finlayson
Journal:  J Vasc Surg       Date:  2010-04-10       Impact factor: 4.268

3.  Long-term outcomes after endovascular abdominal aortic aneurysm repair: the first decade.

Authors:  David C Brewster; John E Jones; Thomas K Chung; Glenn M Lamuraglia; Christopher J Kwolek; Michael T Watkins; Thomas M Hodgman; Richard P Cambria
Journal:  Ann Surg       Date:  2006-09       Impact factor: 12.969

Review 4.  Endovascular abdominal aortic aneurysm repair.

Authors:  M G A Norwood; G M Lloyd; M J Bown; G Fishwick; N J London; R D Sayers
Journal:  Postgrad Med J       Date:  2007-01       Impact factor: 2.401

5.  An endoluminal aortic prosthesis infection presenting as pneumoaorta and aortoduodenal fistula.

Authors:  Yung-Ta Kao; Chun-Ming Shih; Feng-Yen Lin; Nai-Wen Tsao; Nen-Chung Chang; Chun-Yao Huang
Journal:  World J Gastroenterol       Date:  2012-10-07       Impact factor: 5.742

6.  Type I Endoleak-like Phenomenon Causing Rupture of the Replaced Aneurysm Sac 12 Years after Open Repair of Abdominal Aortic Aneurysm.

Authors:  Masahiro Matsushita; Teruo Ikezawa; Hiroshi Banno
Journal:  Ann Vasc Dis       Date:  2008-09-25

7.  An in Vitro Twist Fatigue Test of Fabric Stent-Grafts Supported by Z-Stents vs. Ringed Stents.

Authors:  Jing Lin; Robert Guidoin; Jia Du; Lu Wang; Graeham Douglas; Danjie Zhu; Mark Nutley; Lygia Perron; Ze Zhang; Yvan Douville
Journal:  Materials (Basel)       Date:  2016-02-16       Impact factor: 3.623

8.  Clinical features, management, and outcome of iliopsoas abscess associated with cardiovascular disorders: a hospital-based observational case series study.

Authors:  Sung-Yuan Hu; Ming-Shun Hsieh; Yao-Tien Chang; Chih-Che Huang; Che-An Tsai; Chung-Lin Tsai; Chiann-Yi Hsu; Chia-Hui Shen; Yan-Zin Chang
Journal:  BMC Musculoskelet Disord       Date:  2019-10-25       Impact factor: 2.362

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.